En-1
1. SAFETY PRECAUTIONS
• Besuretoreadthismanualthoroughlybeforeinstallation.
• Thewarningsandprecautionsindicatedinthismanualcontainimportantinformation
pertainingtoyoursafety.Besuretoobservethem.
• Handthismanual,togetherwiththeoperatingmanual,tothecustomer.Requestthe
customertokeepthemonhandforfutureuse,suchasforrelocatingorrepairingthe
unit.
WARNING
Indicatesapotentiallyorimminentlyhazardoussituation
which,ifnotavoided,couldresultindeathorseriousinjury.
CAUTION
Indicatesapotentiallyhazardoussituationthatmayresultin
minorormoderateinjuryordamagetoproperty.
WARNING
•Installationofthisproductmustbedonebyexperiencedservicetechniciansorprofes-
sionalinstallersonlyinaccordancewiththismanual.Installationbynon-professional
orimproperinstallationoftheproductmightcauseseriousaccidentssuchasinjury,
waterleakage,electricshock,orre.Iftheproductisinstalledindisregardofthe
instructionsinthismanual,itwillvoidthemanufacturer’swarranty.
•Donotturnonthepoweruntilallworkhasbeencompleted.Turningonthepowerbe-
foretheworkiscompletedcancauseseriousaccidentssuchaselectricshockorre.
•Ifrefrigerantleakswhenyouareworking,ventilatethearea.Iftheleakingrefrigerant
isexposedtoadirectame,itmayproduceatoxicgas.
•Installationmustbeperformedinaccordancewithregulations,codes,orstandardsfor
electricalwiringandequipmentineachcountry,region,ortheinstallationplace.
•Donotusemeanstoacceleratethedefrostingprocessortoclean,otherthanthose
recommendedbythemanufacturer.
•Thisapplianceisnotintendedforusebypersons(includingchildren)withreduced
physical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unless
theyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebya
personresponsiblefortheirsafety.Childrenshouldbesupervisedtoensurethatthey
donotplaywiththeappliance.
CAUTION
•Readcarefullyallsafetyinformationwritteninthismanualbeforeyouinstallorusethe
airconditioner.
•Installtheproductbyfollowinglocalcodesandregulationsinforceattheplaceof
installation,andtheinstructionsprovidedbythemanufacturer.
•Thisproductispartofasetconstitutinganairconditioner.Theproductmustnotbe
installedaloneorbeinstalledwithnon-authorizeddevicebythemanufacturer.
•Alwaysuseaseparatepowersupplylineprotectedbyacircuitbreakeroperatingonall
wireswithadistancebetweencontactof3mmforthisproduct.
•Toprotectthepersons,earth(ground)theproductcorrectly,andusethepowercable
combinedwithanEarthLeakageCircuitBreaker(ELCB).
CAUTION
•Thisproductisnotexplosionproof,andthereforeshouldnotbeinstalledinexplosive
atmosphere.
•Toavoidgettinganelectricshock,nevertouchtheelectricalcomponentssoonafter
thepowersupplyhasbeenturnedoff.Afterturningoffthepower,alwayswait5min-
utesormorebeforeyoutouchtheelectricalcomponents.
•Thisproductcontainsnouser-serviceableparts.Alwaysconsultexperiencedservice
techniciansforreparing.
•Whenmovingorrelocatingtheairconditioner,consultexperiencedservicetechnicians
fordisconnectionandreinstallationoftheproduct.
•Donotplaceanyotherelectricalproductsorhouseholdbelongingsundertheproduct.
Condensationdrippingfromtheproductmightgetthemwet,andmaycausedamage
ormalfunctiontotheproperty.
•Becarefulnottoscratchtheairconditionerwhenhandlingit.
•Afterinstallation,explaincorrectoperationtothecustomer,usingtheoperatingmanual.
2. ABOUT THIS PRODUCT
2.1. Precautions for using R410A refrigerant
The basic installation work procedures are the same as conventional refrigerant (R22)
models.
However, pay careful attention to the following points:
Sincetheworkingpressureis1.6timeshigherthanthatofconventionalrefrigerant(R22)
models,someofthepipingandinstallationandservicetoolsarespecial.(Seethetable
below.)
Especially,whenreplacingaconventionalrefrigerant(R22)modelwithanewrefrigerant
R410Amodel,alwaysreplacetheconventionalpipingandarenutswiththeR410A
pipingandarenuts.
ModelsthatuserefrigerantR410Ahaveadifferentchargingportthreaddiameter
topreventerroneouschargingwithconventionalrefrigerant(R22)andforsafety.
Therefore,checkbeforehand.[ThechargingportthreaddiameterforR410Ais
1/2-20UNF]
Bemorecarefulthatforeignmatter(oil,water,etc.)doesnotenterthepipingthanwith
refrigerant(R22)models.Also,whenstoringthepiping,securelysealtheopeningby
pinching,taping,etc.
Whenchargingtherefrigerant,takeintoaccounttheslightchangeinthecompositionof
thegasandliquidphases.Andalwayschargefromtheliquidphasewhererefrigerant
compositionisstable.
AIRCONDITIONER
WallMountedType
INSTALLATION MANUAL
Contents
1. SAFETYPRECAUTIONS.................................................................. 1
2. ABOUTTHISPRODUCT................................................................... 1
3. GENERALSPECIFICATION............................................................. 2
4. ELECTRICALREQUIREMENT......................................................... 2
5. SELECTINGTHEMOUNTINGPOSITION....................................... 3
6. INSTALLATIONWORK..................................................................... 3
7. ELECTRICALWIRING..................................................................... 5
8. FINISHING........................................................................................ 6
9. FRONTPANELREMOVALANDINSTALLATION............................. 7
10. TESTRUN......................................................................................... 7
11. REMOTECONTROLLERINSTALLATION........................................ 7
12. OPTIONALKITINSTALLATION....................................................... 7
13. SELECTINGTHEREMOTECONTROLLERCUSTOMCODE........ 8
14. FUNCTIONSETTING........................................................................ 8
15. CUSTOMERGUIDANCE................................................................ 10
16. ERRORCODES.............................................................................. 10
PARTNo.9387082050
Forauthorizedservicepersonnelonly.[Originalinstructions]
English
Deutsch
FrançaisEspañol
Italiano
EλληvIkά
PortuguêsРусскийTürkçe
9387082050_IM.indb 1 12/10/2015 13:33:19
AMP Air Conditioning
www.ampair.co.uk | sales@ampair.co.uk

Other manuals for Fujitsu ASYG36LMTA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYG36LMTA and is the answer not in the manual?

Fujitsu ASYG36LMTA Specifications

General IconGeneral
BrandFujitsu
ModelASYG36LMTA
CategoryAir Conditioner
LanguageEnglish

Related product manuals