|Host port protocol|
3. Using the feature pack submodel ID, locate the corresponding Controller submodel ID for the starting
configuration and find the Feature Activation Code for the desired ending configuration within the table
below. Then, copy that Feature Activation Code to a text file.
Note: Baseboard ports are disabled when running an NVMe protocol on the HIC.
Note: If you are not using the IB HIC, you can ignore the HIC Ports column in the following tables:
Table 1: Encryption Capable Feature Activation Codes (Baseboard Port Only Conversions)
Starting Configuration Ending Configuration
Controller
submodel ID
Ports to
Convert
Controller
Submodel ID
Ports
Converted To
Feature Activation Code
360 FC baseboard
ports
362 iSCSI
baseboard
ports
SGL-2SB-ZEX13
362 iSCSI
baseboard
ports
360 FC baseboard
ports
5GI-4TB-ZW3HL
Table 2: Encryption Capable Feature Activation Codes
Starting configuration Ending configuration
Controller
Submodel ID
Baseboard
Ports
HIC
Ports
Controller
Submodel
ID
Baseboard
Ports
HIC
Ports
Feature
Activation Code
361 FC SRP UGG-XSB-ZCZKU
362 iSCSI iSER SGL-2SB-ZEX13
363 iSCSI SRP VGN-LTB-ZGFCT
382 Not Available NVMe/IB KGI-ISB-ZDHQF
360 FC iSER
403 Not Available NVMe/
RoCE or
NVMe/
FC
YGH-BHK-Z8EKB
360 FC iSER JGS-0TB-ZID1V
362 iSCSI iSER UGX-RTB-ZLBPV
363 iSCSI SRP 2G1-BTB-ZMRYN
382 Not Available NVMe/IB TGV-8TB-ZKTH6
361 FC SRP
403 Not Available NVMe/
RoCE or
NVMe/
FC
JGM-EIK-ZAC6Q
360 FC iSER 5GI-4TB-ZW3HL
361 FC SRP EGL-NTB-ZXKQ4
363 iSCSI SRP HGP-QUB-Z1ICJ
383 Not Available NVMe/IB BGS-AUB-Z2YNG
362 iSCSI iSER
403 Not Available NVMe/
RoCE or
NVMe/
FC
1GW-LIK-ZG9HN
95