4.4 Audit Log Setup
Audit trail logs (hereinafter referred to as "audit log") that record performed operations by using the ETER-
NUS DX and the system actions that are associated with these operations can be sent to the specified Syslog
server (external server).
Up to two Syslog servers can be set.
After the environmental settings for audit logs are complete, confirm that the audit log is successfully
received on the Syslog server.
Even if a communication error occurs between the ETERNUS DX and the Syslog server, the audit log is
not sent again.
The audit log setting is explained below.
1 On the navigation of the ETERNUS Web GUI screen, click [System].
The [System] screen appears.
2 In [Category], click [Audit Log].
The [Audit Log] screen appears.
3 If "Disable" is specified for "Audit Log", select "Enable".
(1) Click [Enable Audit Log] in [Action].
A confirmation screen appears.
(2) Click the [OK] button.
Enabling of the audit log starts.
(3) Check the setting completion message and click the [Done] button.
The screen display returns to the [Audit Log] screen.
4 Specify the Syslog server to which the audit log is sent.
(1) Click [Setup Audit Log] in [Action].
The [Setup Audit Log] screen appears.
Select "on (RFC3164)" or "on (RFC5424)" for "Send Audit Log".
To send messages in RFC5424 format to a target Syslog server that supports RFC5424, select
"on (RFC5424)". If this is not the case, select "on (RFC3164)".
Chapter 4
Monitoring Settings
4.4 Audit Log Setup
77