EasyManua.ls Logo

Fujitsu Eternus DX80 S2 - Chapter 2 Setting up the ETERNUS DX; Common Settings; Setting the To-Server Connection Type (Setting the FC Port Parameters); Table 2.1 FC Port Parameter Settings (FC-AL Connection)

Fujitsu Eternus DX80 S2
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2
Setting Up the ETERNUS DX
2.1 Common Settings
This section explains the settings required for all server OSs, regardless of the connection configuration.
See the "ETERNUS Web GUI User's Guide" for details of how to set up and operate ETERNUS Web GUI.
2.1.1 Setting the To-server Connection Type (Setting the FC Port Parameters)
For each connection configuration, set the indicated items only. Retain the default values for all of the pa-
rameters that are not described below.
Specify "Fabric connection" for connections to the Fibre Channel switches.
Specify "FC-AL connection" for direct connections to the Fibre Channel cards. Specify "Fabric connection" for
direct connections to 16Gbit/s Fibre Channel cards (maximum transfer rate) with a transfer rate of 16Gbit/s.
Table 2.1 FC port parameter settings (FC-AL connection)
Parameter
Solaris OS
HP-UX, AIX, Windows
®
, Linux, VMware
ESX, PAN Manager, Citrix XenServer,
Oracle Linux, Oracle VM Server for x86
Connection FC-AL
Set Loop ID Manual
Loop ID Values from 0x10 upwards
(Except 0x7D)
0x00
Transfer Rate See the table below (*1)
FC Frame Size 2048
Reset Scope I_T_L
Release Reservation if Chip is Reset Disable