AP-7
For details on the cleaning the ADF, refer to Chapter 4 "DAILY CARE OF THE EQUIPMENT" of
the "fi-5750C Operator Guide".
Locations and Cycle for Cleaning
TABLE 5.
Part to Clean
Standard Cleaning
Cycle using Cleaner
F1
Standard Cleaning
Cycle using Cleaning
Paper with Cleaner F1
Standard Cleaning
Cycle using Cleaner
F2
Clean these parts
after every 10,000
scans.
Clean these parts
after every 10,000
scans.
Clean these parts
when dirty.
Flat Bed Document Holding Pad
3
Document Bed
3
ADF Chute Roller
3
Pick Arm
3
Pick Roller Set
33
Brake Roller
33
Feed Rollers
33
Plastic Rollers
333
Sheet Guide
33
Glass
3
Ultra Sonic Sensor Clean this part with a dry lint-free dry cloth.
ATTENTION
The scanner must be cleaned more frequently if you scan any of the following type of documents.
Documents of coated paper.
Documents that are almost completely covered with printed text or graphics.
Chemically treated documents such as carbonless paper
Documents containing a large amount of calcium carbonate
Handwritten documents