KEEP THIS OPERATION MANUAL
FOR FUTURE REFERENCE
FUJITSU GENERAL LIMITED
OPERATING MANUAL
P/N9316796003-01
HEAT & COOL MODEL
(REVERSE CYCLE)
ROOM AIR CONDITIONER
FLOOR TYPE
R410A
REFRIGERANT
This Air Conditioner contains and operates
with refrigerant R410A and Polyol Ester oil.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance and/or service of this product.
07J353_9316796003-01_cover.p65 2007.09.25, 19:321

Questions and Answers

  • R
    richard33Aug 15, 2025
    What to do if my Fujitsu Inverter 9316796003-01 Air Conditioner doesn't operate at all?
    • R
      Roger DaughertyAug 15, 2025
      If your Fujitsu Air Conditioner doesn't operate at all, first check for a power failure. Next, verify whether a fuse has blown or a circuit breaker has tripped. Finally, check if the timer is operating.
  • Y
    youngalexandraAug 18, 2025
    Why is water produced from the outdoor unit of my Fujitsu Air Conditioner?
    • M
      Matthew OrtizAug 19, 2025
      During Heating operation, water may be produced from the outdoor unit due to Automatic Defrosting operation.
  • J
    Julia StephensonAug 21, 2025
    How to fix a Fujitsu Inverter 9316796003-01 that doesn't operate immediately?
    • T
      Thomas CurryAug 21, 2025
      If the unit is stopped and then immediately started again, the compressor will not operate for about 3 minutes to prevent fuse blowouts. Also, whenever the electrical breaker is turned off then on again or the power supply plug is disconnected and then reconnected, the protection circuit will operate for about 3 minutes, preventing unit operation during that period.
  • A
    asandersAug 26, 2025
    What to do if my Fujitsu Inverter 9316796003-01 Air Conditioner operates differently from the Remote Control Unit’s setting?
    • L
      Lisa BoydAug 26, 2025
      If your Fujitsu Air Conditioner unit operates differently from the Remote Control Unit’s setting, check if the Remote Control Unit’s batteries are dead or if the Remote Control Unit’s batteries are loaded properly.
  • R
    Raymond MillerAug 29, 2025
    Why is my Fujitsu Inverter 9316796003-01 Air Conditioner performing poorly?
    • A
      andersonhannahAug 29, 2025
      Poor performance of your Fujitsu Air Conditioner can stem from several factors. Check if the air filter is dirty or if the unit's intake grille or outlet port is blocked. Ensure the thermostat settings are correct. Closing any open windows or doors can help, as well as drawing curtains to block direct sunlight during Cooling operation. Also, consider whether there are too many heat-generating devices or people in the room. Ensure that the lower air outlet is not obstructed and that the unit is not set to SUPER QUIET operation.
  • S
    Seth LeeSep 1, 2025
    Why is the airflow weak or stopped in my Fujitsu Air Conditioner?
    • R
      Robert AguilarSep 1, 2025
      Weak airflow or a complete stop in your Fujitsu Air Conditioner can occur for several reasons. When Heating starts, the fan speed is initially low to allow internal parts to warm up. If the room temperature exceeds the thermostat setting during Heating, the outdoor unit will stop, and the indoor unit will operate at a very low fan speed; adjust the thermostat higher if needed. The unit may also temporarily stop for 7 to 15 minutes during Automatic Defrosting (the OPERATION Indicator Lamp will flash). Additionally, the fan might operate at a very low speed during Dry operation, when the unit is monitoring the room's temperature, during SUPER QUIET operation, or in monitor AUTO operation.
  • T
    Timothy JimenezSep 4, 2025
    Why does my Fujitsu Air Conditioner emit mist or steam?
    • C
      chelseawatkinsSep 4, 2025
      The mist or steam emitted from your Fujitsu Air Conditioner has normal causes. During Cooling or Dry operation, a thin mist may appear due to the sudden cooling of room air, causing condensation. During Heating, steam from the outdoor unit may occur during Automatic Defrosting operation, when the outdoor unit's fan may stop.
  • M
    Michele WilliamsSep 7, 2025
    Why is there noise coming from my Fujitsu Inverter 9316796003-01?
    • V
      Veronica PerezSep 7, 2025
      The sound of water flowing may be heard during or immediately after operation. Increased noise may be noticeable for about 2 to 3 minutes after starting. During Heating, a sizzling sound may occur occasionally due to Automatic Defrosting.
  • N
    Nicholas PorterSep 12, 2025
    Why does my Fujitsu Inverter 9316796003-01 smell?
    • J
      Joe SmithSep 12, 2025
      A smell from your Fujitsu Air Conditioner's indoor unit can result from room odors like furniture or tobacco being drawn into the system.

Summary

R410 A Refrigerant Safety

Safety Precautions

Preparation

Loading Remote Batteries

Instructions for inserting batteries into the remote control unit.

Setting the Current Time

Procedure to set the current time on the remote control unit.

Operation

Selecting Operation Mode

Steps to start the unit and select the desired operating mode.

Setting the Thermostat

Instructions for adjusting the desired room temperature setting.

Setting Fan Speed

How to adjust the fan speed (Auto, High, Med, Low, Quiet).

Stopping Operation

Procedure to turn off the air conditioner unit.

Mode Operation Explanations

Details on Heating, Cooling, Dry, and Fan modes.

Timer Operation

Setting ON;OFF Timers

Steps to set a single ON or OFF timer for the air conditioner.

Setting Program Timers

How to set a sequence of ON and OFF timers within a 24-hour period.

Sleep Timer Operation

Activating the Sleep Timer

Steps to set the sleep timer for automatic operation stop.

Sleep Timer Functionality

Explanation of how the sleep timer adjusts temperature and stops operation.

Adjusting Air Circulation Direction

10°C Heat Operation

Economy Operation

Cleaning and Care

Cleaning the Intake Grille

Step-by-step guide to cleaning the air conditioner's intake grille.

Cleaning the Air Filter

Instructions for cleaning the air filter with vacuum or water.

Air Cleaning Filter Installation

Instructions for installing air cleaning filters into the unit.

Replacing Air Cleaning Filters

Procedure for replacing used air cleaning filters with new ones.

Troubleshooting

Normal Operation Troubleshooting

Addresses common issues like noise, smells, airflow, and damper behavior during normal use.

Unit Not Operating Checks

Steps to diagnose why the air conditioner is not operating at all.

Performance and Setting Issues

Troubleshooting poor performance and discrepancies with remote control settings.

Fujitsu Inverter 9316796003-01 Specifications

General IconGeneral
BrandFujitsu
ModelInverter 9316796003-01
CategoryAir Conditioner
LanguageEnglish

Related product manuals