RX200 S7 Operating Manual 19
Functional overview
Accessible drives / components
The variant with a maximum of four 2.5-inch HDD modules provides a bay for 
an optical drive.
The optical drive installed here cannot be replaced during operation.
USB connectors
The two USB 2.0 connectors on the front of the server support activities carried 
out by the service technician. The maximum length of the external cable are 
three meters.
Another three USB 2.0 connectors are available on the rear of the device. 
Power supply
In its basic configuration the server uses a hot-plug power supply unit (450 W 
or 800 W), that adjusts automatically to any mains voltage in the range of 100 - 
240 V. As an option, the power supply can be expanded with an extra power 
supply unit to create a redundant power supply. If a power supply unit fails, the 
redundant configuration assures continued operation. The defective power 
supply unit can be replaced during operation. A mix of 450 W and 800 W PSUs 
is not allowed. In case of mixed configuration CSS LED will be flashing and an 
SEL entry will be generated (for further details see the "PRIMERGY RX200 S7 
Server Upgrade and Maintenance Manual").
Cooling
The Cool-safe™ cooling concept with improved air flow cooling technology 
(honeycomb design) ensures the highest possible performance of the 
processors at work; at the same time, the system is extremely reliable thanks to 
the reduced heat dissipation.
Base units are supplied with four hot-plug fan modules (single CPU 
configuration and depending on CPU type) or six hot-plug fan modules (two 
CPUs configuration and depending on CPU type). Each fan module consists of 
two fans, implemented in one housing.
Base units with four fan modules operate in a 1 of 4 redundancy, base units with 
six fan modules operate in a 1 of 6 redundancy. In other words, if one of the four 
or six fan modules fails, the system will operate without any problem.
For further details see the "PRIMERGY RX200 S7 Server Upgrade and 
Maintenance Manual".