Functional overview
Dimensions / Weight
Ventilation clearance
At least 200 mm on the front and rear.
Ambient conditions
Condensation during operation must be avoided!
Noise level (depending on the configuration)
The acoustic noise values are depending on the system configuration.
Rack (W x D x H) 482.6 mm (Bezel) / 444.8 mm (Body) x 765.0 mm x
176.0 mm
Mounting Depth Rack 728 mm
Height Unit Rack 4 U
19" rackmount Yes
Mounting cable depth
rack
100 mm (1000 mm rack recommended)
Weight minimum 32 kg; maximum 46 kg (actual weight may
vary depending on configuration)
Rack integration kit rack integration kit as option
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2) 5°C ... 40°C (with Cool-safe
®
ATD)
10°C ... 35°C (without Cool-safe
®
ATD)
Transport (2K2) -25°C ... 60°C
Humidity 10% ... 85% (non condensing)
Sound power level L
WAd
(ISO 9296) < 6.5 B (standby)
< 6.6 B (operation)
Sound pressure level at bystander position L
pAm
(ISO 9296) (at < 23 °C)
< 50 db(A) (standby)