Data Sheet FUJITSU Server PRIMERGY TX140 S1p Mono-Socket Intel® Xeon® processor server
Page 6 / 9 www.fujitsu.com/fts
Server Management
Option ServerView Suite - Deploy
SV Deployment Manager (full version)
ServerView Suite - Maintain
iRMC Advanced Pack incl. Advanced Video Redirection (AVR) and Remote Storage
ServerView Suite - Integrate
SV Integration pack for Fujitsu ManageNow® solution
Server Management notes Regarding Operating System dependencies and product details for ServerView Suite Software Products see dedicated
Product Data sheets.
Dimensions / Weight
Floor-stand (W x D x H) 205 x 584 x 444 mm
Rack (W x D x H) 482 x 570 x 220 mm
Dimension notes Floorstand Width 306 mm with tilt protection; depth measured excludes handles on redundant PSU. Rack depth
excludes handles of redundant PSU and rack front.
Height Unit Rack 5 U
Weight 21-28 kg
Weight notes Actual weight may vary depending on conguration
Rack integration kit Rack integration kit as option
Environmental
Operating ambient temperature 10 - 35 °C
Operating relative humidity 10 - 85 % (non condensing)
Operating environment FTS 04230 – Guideline for Data Center (installation specication)
Operating environment Link http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
Sound pressure (LpAm) SATA: 25 dB(A) idle mode/ 25 dB(A) operation mode; SAS: 31 dB(A) idle mode/ 33 dB(A) operation mode
Sound power (LWAd; 1B = 10dB) SATA: 4.2 B idle mode/ 4.2 B operation mode ; SAS: 4.9 B idle mode/ 5.1 B operation mode
Noise notes Noise emissions and operation modes depend on system conguration.
Electrical values
Power supply conguration 1x standard, 1x hot-plug or 2x redundant hot-plug
Max. output of single power supply 450 W
Standard power supply output 300 W (90% efciency)
Hot-plug power supply output 450 W (94% efciency)
Hot-plug power supply redundancy Yes
Rated voltage range 100 V - 240 V
Rated frequency range 47 Hz - 63 Hz
Rated current max. 6 A / 3 A (100 V / 240 V)
Active power (max. conguration) 216 W
Active power note To estimate the power consumption of different congurations use the Power Calculator of the System Architect:
http://congurator.ts.fujitsu.com/public/
Apparent power (max. conguration) 247 VA
Heat emission 777.6 kJ/h (737.0 BTU/h)
Power Supply Notes The active power and apparent power values may change according to conguration.
Compliance
Germany GS
Europe CE Class A *
USA/Canada CSA us
ULc/us
FCC Class A
Global CB
RoHS (Restriction of hazardous substances)
WEEE (Waste electrical and electronical equipment)
ENERGY STAR®
Japan VCCI
Russia GOST-R