EasyManuals Logo

Fujitsu PRIMERGY TX2550 M4 User Manual

Fujitsu PRIMERGY TX2550 M4
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
TX2550 M4 Operating Manual 63
Starting up and operation
3
Global Error
indicator,
see also
"iRMC-
related
status
signals" on
page 64
off
No critical event detected (non CSS
component).
orange on
Prefailure event detected (non CSS
component).
orange
flashing
Non CSS component failure detected.
Possible causes:
System is out of the specified
temperature range
Defective sensor
–CPU error
Error detected by server
management software
4
HDD/SSD
activity
indicator
green
flashing
Data access in progress.
5
Power-on
indicator
off The server is switched off.
green on
The server has been switched on
but Power Cycle Delay settings
delay it from turning on for a
specified time.
The server is switched on and
operating normally.
green
flashing
slowly
The iRMC firmware is starting up after
the server has been connected to the
mains.
Pos. Label Indicator Status Description
!

Table of Contents

Other manuals for Fujitsu PRIMERGY TX2550 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX2550 M4 and is the answer not in the manual?

Fujitsu PRIMERGY TX2550 M4 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX2550 M4
CategoryServer
LanguageEnglish

Related product manuals