Error Contents :
Main PCB Error
Symptom :
Error Code display [ C 1 ]
All the control items do not operate.
Details :
Condition of occurrence : Synchronization of Network Device was not normally done.
Release condition : When the synchronization of the device is normally done.
Cause 1 : External noise
After pressing SW104 of Network Convertor PCB for 5 seconds or turning on power.
Does error code display reappear?
Cause 2 : Network Convertor is defective.
Replace Network Convertor.
It is not a defect of PCB. Remove the surrounding noise source.Remove the surrounding noise source.
YES
OK
NO
Trouble shooting 84
Network Convertor (UTY-VGGXZ1)-
04-92