3-3-3 Individual Hold
“Individual Hold” can be used only with cassette type indoor
unit which supports this function. The air ow direction can
be set for each outlet of single or multiple indoor units con-
nected to this remote controller.
(1) Touch the [Individual Hold] on
the “Air Flow Direction Setting”
screen.
1
Air Flow Direction Setting
Back
Individual Hold
VT
Setting
Swing
HZ
Setting
(2) Touch the unit number you
want to set on the “Individual
Hold” screen.
01-01
01-05
01-02
01-06
01-03
01-07
01-04
01-08
Individual Hold
Page 1/ 2
Back
Reset
Next
Page
Unit 1
Unit 5
Unit 2
Unit 6
Unit 3
Unit 7
Unit 4
Unit 8
* [Comfort] is set to the shaded indoor unit as shown (2a)
below. When it is touched, the message is displayed
as shown (2b) below.
(2a) (2b)
01-01
01-05
01-02
01-06
01-03
01-07
01-04
01-08
Individual Hold
Page 1/ 2
Back
Reset
Next
Page
Unit 1
Unit 5
Unit 2
Unit 6
Unit 3
Unit 7
Unit 4
Unit 8
Close
Individual Hold
Air flow direction setting cannot be performed.
Set the Comfort to "Disable".
* When multiple indoor units are connected to this
remote controller,the indoor unit selection screen is
displayed. When the screen (2) has 2 pages, they can
be switched by touching the [Next Page] or [Previous
Page]. When this remote controller is connected to
multiple indoor units, the address (XX-XX) is displayed
for each indoor unit. Touch the indoor unit to be set. [
]
is displayed at the set indoor units.
NOTES
To clear the air ow direction setting of all the
displayed indoor units, touch [Reset]. When [Yes]
of the con rmation screen is touched, the setting is
cleared and switches to the air ow direction setting
of “VT setting” (Refer to 3-3-1).
When you want to change the order of the indoor
units displayed on the indoor unit selection screen,
consult your installer or service personnel.
(3) The outlet port selection screen that sets the air ow
direction is displayed. Touch the outlet port to be set.
Casette type
Check the position of each outlet port based on “
” mark
of the indoor unit body.
Position of the mark
Indoor Unit 1
(
00-00
)
Back Reset
Outlet 1 Outlet 2
Outlet 3 Outlet 4
NOTE
To clear all outlet port settings of selected indoor
units, touch [Reset]. When [Yes] of the con rma-
tion screen is touched, the setting is cleared and
switches to the air ow direction setting of “VT set-
ting” (Refer to 3-3-1).
3D ow cassette type
The number of outlet port di ers depending on the model.
Indoor Unit 1
(
00-00
)
Left RightCenter 2Center 1
Back Reset
Indoor Unit 1
(
00-00
)
Left RightCenter
Back Reset
(4) The air ow direction setting screen is displayed. Touch
[VT] or [HZ].
When the indoor unit does not have a ow direction
adjustment function(vertical/horizontal),[VT Setting]/[HZ
Setting] is not displayed and the air ow direction cannot
be set.
VT Setting
VT Air Flow Direction Setting” screen is displayed. Touch
[ ]
or
[ ]
and set the air ow direction or “Swing.
Indoor Unit 1
(
00-00
)
1
VT
1
HZ
Back
1
Indoor Unit 1
(
00-00
)
Cancel OK
Outlet 1
HZ Setting
HZ Air Flow Direction Setting” screen is displayed. Touch
[
] or [ ] and set the air ow direction or “Swing.
Indoor Unit 1
(
00-00
)
VT
1
HZ
Back
1
1
Indoor Unit 1
(
00-00
)
Cancel OK
Center
HZ
Setting
NOTE
When the air ow direction setting of “VT setting”(Refer
to 3-3-1) or “HZ setting”(Refer to 3-3-2) is set at the
outlet port, “—” is displayed at the outlet port screen.
3-4 Timer Setting
(1) Touch the [Timer Setting] on the “Main Menu” screen.
(2) Timer Setting” screen is displayed.
(1) (2)
Monitor
Next
Page
Page 1/ 3
Main Menu
Air Flow Direction
Setting
Weekly Timer
Setting
Timer Setting
Comfort
Back
On Timer [Disable]
[Disable]
[Disable]
Off Timer
Auto Off Timer
Timer Setting
The following timer settings are possible:
• On Timer:
The stopped indoor unit starts to operate after the set
time.
• O Timer:
The operating indoor unit stops to operate after the set
time.
• Auto O Timer:
When indoor unit operation is started by the On/O
button of this unit, operation stops after the set time.
When the item to be set is touched, the display switches
to each setting screen. When each setting is complete
or canceled, the display returns to this screen. When
[Back] is touched, the display returns to the “Main
Menu” screen.
En-10
9373329831-02OMEnUTY-RNRT.indd109373329831-02OMEnUTY-RNRT.indd10 2021/11/1913:23:032021/11/1913:23:03