2 CONTROL
2-1 On and O
(1) Press the [On/O ] button.
26.0
26.0
°C
°C
Cool
Set Temp.
Mode Fan
Fri 10:00AM
Auto
Zone MenuStatus
On/O button
Power indicator
lamp
The Power indicator lamp remains lit while the indoor
unit is operating.
NOTE
The On/OFF button cannot be operated at screens other
than the monitor mode screen.
2-2 Operation Settings
2-2-1 Set the Operation Mode
(1) Touch the [Mode] on the monitor mode screen.
(2) Mode” screen is displayed. Select the operation mode.
(1) (2)
Zone
26.0
26.0
°C
°C
Cool
Auto
Set Temp.
Mode
MenuStatus
Fan
Fri 10:00AM
Mode
Cancel
Cool Dry Heat
Fan
OK
Auto
Depending on the model of
the indoor unit, [Custom Auto]
is displayed instead of [Auto].
26.26.0
°C
Custom
Auto
Set Te
Mode
Dry Heat
Fan
OK
Custom
Auto
NOTES
Only selectable modes are displayed. The select-
able modes may be di erent depending on the
system con guration and operation status. Refer
to [4 OPERATION TIPS][4-1 Selectable modes].
When the “Fan” is selected,
the temperature cannot be
set.
Fan
Auto
Set Temp.
Mode
MenuStatus
Fan
Fri 10:00AM
[Auto] or [Custom Auto] mode can be used in the
R.C. Group to which Master Indoor Unit is set. It is
not displayed at other R.C. Group.
When the operation mode is switched in a heat
recovery system, operation preparations may take
some time, but this is not a malfunction.
(3) When the [OK] is touched, the display returns to the
monitor mode screen.
2-2-2 Set the Temperature
(1) Touch the [Set Temp.] on the monitor mode screen.
(2) “Set Temp.” screen is displayed. Adjust the room tem-
perature with the [
] or [ ].
(1) (2)
Zone
26.0
26.0
°C
°C
Cool
Auto
Set Temp.
Mode
MenuStatus
Fan
Fri 10:00AM
26.0
26.0
°C
°C
Set Temp.
Cancel OK
When the operation mode is
set to [Custom Auto], set the
cooling and heating tempera-
ture.
20.0
28.0
°C°C
Set Temp.
Cancel OK
HeatCool
NOTES
The settable temperature range is di erent depend-
ing on the operation mode. Refer to [4 OPERA-
TION TIPS][4-3 Selectable Temperature Range].
When the “Set Temp. Range Setting” is set, the se-
lectable temperature conforms to the setting. Refer
to [3 SETTING] [3-6 Special Setting] [3-6-3
Set Temp. Range Setting].
(3) When the [OK] is touched, the display returns to the
monitor mode screen.
2-2-3 Set the Fan Speed
(1) Touch the [Fan] on the monitor mode screen.
(2) Fan” screen is displayed. Select the fan speed with the
[
] or [ ].
(1) (2)
Zone
26.0
26.0
°C
°C
Cool
Auto
Set Temp.
Mode
MenuStatus
Fan
Fri 10:00AM
Fan
Cancel OK
Auto
(3) When the [OK] is touched, the display returns to the
monitor mode screen.
2-3 Zone Operation
2-3-1 Zone Select
Touch the [Zone] on the monitor
mode screen.
Zone
26.0
26.0
°C
°C
Cool
Auto
Set Temp.
Mode
MenuStatus
Fan
Fri 10:00AM
The “Zone Select” screen is dis-
played.
[ ]
Zone Select
Zone
Operation
Sensor
Method
Priority
Sensor
Zone Group Operation
Group3
Back
NOTES
If not connected to the zone interface, this item is not
displayed on the monitor mode screen.
This item is controllable only when the air conditioner is
operating.
En-7