- 13 -
Line Function
Setting range
or display
Setting
increment
Basic
setting
Time program heating / cooling, circuit 1
500 Pre-selection (Day / Week) Mon-Sun, Mon-Fri, Sat-Sun,
Monday, Tuesday, …
Mon-Sun
501 1st phase On (start) 00:00... --:-- 10 min 6:00
502 1st phase O󰀨 (end) 00:00... --:-- 10 min 22:00
503 2nd phase On (start) 00:00... --:-- 10 min --:--
504 2nd phase O󰀨 (end) 00:00... --:-- 10 min --:--
505 3rd phase On (start) 00:00... --:-- 10 min --:--
506 3rd phase O󰀨 (end) 00:00... --:-- 10 min --:--
516 Default values, Circuit 1 No, Yes No
Yes + OK: The default values memorised in the regulator replace and cancel the customised heating programs.
Your customised settings are therefore lost.
Time program heating / cooling, circuit 2
Only with the 2nd circuit kit option.
520 Pre-selection (Day / Week) Mon-Sun, Mon-Fri, Sat-Sun,
Monday, Tuesday, …
Mon-Sun
521 1st phase On (start) 00:00... --:-- 10 min 6:00
522 1st phase O󰀨 (end) 00:00... --:-- 10 min 22:00
523 2nd phase On (start) 00:00... --:-- 10 min --:--
524 2nd phase O󰀨 (end) 00:00... --:-- 10 min --:--
525 3rd phase On (start) 00:00... --:-- 10 min --:--
526 3rd phase O󰀨 (end) 00:00... --:-- 10 min --:--
536 Default values, Circuit 2 No, Yes No
Yes + OK: The default values memorised in the regulator replace and cancel the customised heating programs.
Your customised settings are therefore lost.
Time program 4 / DHW
If the installation is tted with the DHW kit.
560 Pre-selection (Day / Week) Mon-Sun, Mon-Fri, Sat-Sun,
Monday, Tuesday, …
Mon-Sun
561 1st phase On (start) 00:00... --:-- 10 min 00:00
562 1st phase O󰀨 (end) 00:00... --:-- 10 min 05:00
563 2nd phase On (start) 00:00... --:-- 10 min 14:30
564 2nd phase O󰀨 (end) 00:00... --:-- 10 min 17:00
565 3rd phase On (start) 00:00... --:-- 10 min --:--
566 3rd phase O󰀨 (end) 00:00... --:-- 10 min --:--
576 Default values No, Yes No
Yes + OK: The default values memorised in the regulator replace and cancel the customised heating programs.
Your customised settings are therefore lost.
Holidays, heating circuit 1 (For the Holiday program is active, the heating mode should be on AUTO).
641 Preselection Period 1 to 8 Period 1
642 Period Start (Day / Month) 01.01... 31.12 1
643 Period End (Day / Month) 01.01... 31.12 1
648 Operating level Frost protection, Reduced Frost
protection
Waterstage / OPERATING INSTRUCTIONS / 2010 - EN