- (OU01 - 09) -
Outdoor unit / Single phase
OUTDOOR UNIT
WO
G112-140LCTA
OUTDOOR UNIT
WO
G112-140LCTA
ELECTRICAL SPECIFICATIONS2-5.
Model name (Outdoor unit) WO
Û
G112LCTA WO
Û
G140LCTA
Available voltage range V 198 - 264
Power supply
Voltage V 230
Frequency Hz 50
*1) Max. operating current Heating
A
22 25
*2) Wiring spec.
Main fuse (Circuit breaker) Current 27 32
Power cable mm² 4 6
Wiring connections
For power supply
*3) Quantity
3
For connection with indoor 4
*1) The maximum current is the total current of indoor unit and outdoor unit.
*2) Wiring spec. :
Selected sample
(Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
*3) Included earth wiring.