10. SIGNALS / ALARMS / ERRORS
Open door indication
Operating on the Economic setpoint
Open door alarm
Temperature sensor 2
High room temperature alarm (sensor 1)
Evaporator sensor error: sensor disconnected or damaged
Temperature sensor 3
Temperature sensor 4
Adjust / View the date and time
Low pressure event
High pressure event
High condenser temperature alarm (level 1)
Function lock
External alarm (digital input)
Auxiliary sensor S3 error: sensor disconnected or damaged
Auxiliary sensor S4 error: sensor disconnected or damaged
Clock not set
Contact Full Gauge
Error in choosing the measure to be preferentially displayed on the
display. Parameterize function [F136] - Preferred indication on the
display.
Temperature locked on defrosting cycle
High condenser temperature alarm (level 2)
Control functions off
Audible alarm deactivated
Contact Full Gauge
Reset function values
Room sensor error: sensor disconnected or damaged
Temperature sensor 1
Low room temperature alarm (sensor 1)
Indicates that the final defrosting temperature has not been reached
Flashing LED
Flashing LED
Tray defrosting in the pre-defrost and drain stages or waiting for
Fast Freezing mode indicated
Compressor exceeded maximum on time without reaching control
Low pressure alarm (manual alarm required)
High pressure alarm (manual alarm required)
Compressir maintenance alarm
Low voltage alarm
High voltage alarm
Datalogger memory full
the second evaporator to finish defrosting
temperature (setpoint)
10.1 Signals
10.2 Alarms
10.3 Errors
[F138] - Maximum length of time that the temperature is locked in during defrosting:
During the defrosting process, the last temperature measured in the refrigeration cycle or the [deFr]
message will be kept on the display. The display will be released when the temperature shown is
reached again or the time set for this function has been exceeded, after the start of the next refrigeration
cycle (whichever comes first). If set to the value the temperature display will be frozen only [Off,],
while defrosting.
[F139] - Function lock mode:
Enables and configures the Function Lock (see item 9.3.11).
[,,,0]: Function Lock can't be enabled;
[,,,1]: Enables partial blocking, where the control functions will be blocked but the adjustment of the
setpoints remain released;
[,,,2]: Enables total locking, leaving only access to the functions of the facilitated menu available.
[F140] - Function lock period
With this feature active, the parameters are protected against undue changes and are only available for
viewing. In this condition, when trying to change these values, the message will appear on [LOC,,]
the display.
[F141] - Turns Off control functions:
When the control functions are turned off, the controller starts to operate only as a temperature indicator
with all outputs deactivated. This function can operate in the following ways:
[Off,]: Does not allow the control functions to be turned off;
[,,,1]: Only allows control functions to be turned on or off if the functions are unlocked;
[,,,2]: Allows control functions to be turned on or off even if the functions are locked.
[F142] - Device address on the RS-485 network:
Address of the instrument on the RS-485 network that enables it to communicate with the Sitrad
software.
Note: You may not have any device on the network with the same address.
12. INTERGRATING CONTROLLERS, RS-485 S ERIAL
INTERFACE AND COMPUTER
11. GLOSSARY
- °C: Temperature in degrees Celsius.
- °F: Temperature in degrees Fahrenheit.
- Defr (defrost): Defrosting.
- LOC: Locked.
- No: No.
- OFF: Turned Off/ deactivated.
- ON: Turned On / activated.
- Refr: Refrigeration.
- SET : set or configure.
EASYPROG
- TO COMMUNICATE WITH EASYPROG, THIS EQUIPMENT MUST NOT
BE COMMUNICATING WITH THE SITRAD SOFTWARE.
- PLEASE NOTE THAT THE PRODUCT WILL ONLY BE COMPATIBLE
WITH EASYPROG 6.
IMPORTANT
13. OPTIONAL ITEMS - Sold separately
Extended Panel
Full Gauge Controls extended panel allows controllers to be installed in Evolution and Ri lines (the opening
must measure 71x29mm for the extended panel to be installed), as the opening does not need to be
precise for the device to be properly installed. The panel has space to be branded with the company logo
and contact information, and it has 10A switches (250 V ac) that can be used for switching on internal
lighting, ventilation or fan systems.
EasyProg - version 6 or higher
This is an accessory, whose main function is to store the parameters of the controllers. You can load new
parameters from a controller at any time, and download them to a production line (from the same
controller), for example.
It has three types of connection for loading or clearing parameters:
- Serial RS-485: Connect it to the controller using the RS-485 network
(only controllers that can access RS-485).
- USB: If connected to the computer by a USB port, it can use Sitrad's Program Editor.
- Serial TTL: The controller can connect directly to
EasyProg by a Serial TTL connection.
AB
MT-530
super
AB
MT-530
super
A
A
B B
A B
A
B
A
A
B B
A B
A
A
B B
A B
A
A
B B
A B
*Connecting Block for Serial Communication
Used to connect more than one instrument to the Interface. The wire's
connections must be made in agreement with the following rules: terminal A of
the instrument connects to the terminal A of the connecting block, that must be
connected with the terminal A of the Interface. Repeat the action for terminals B
and , being the cable shield.
*Sold Separately
CONV. 32
or
CONV. 256
Keep Sitrad updated in website:
http://www.sitrad.com
®
Watch Sitrad installation video in:
http://www.fullgauge.com/
videos/sitrad