SECTION VIII. HARDWARE & MAINTENANCE
With a little care and maintenance, your Muse 3D Laser Cutter will remain clean and continue to run
at top efficiency for years to come. Be aware of all safety and maintenance issues with your machine
by following all the safety instructions in this manual.
Replacing the Laser Tube
This section provides procedures and a walkthrough to replace the laser tube on your Muse 3D.
Although it should last for hundreds of projects, the laser tube is considered a consumable and will
eventually need to be replaced. Please carefully read all instructions before beginning the
replacement procedure as there are several critical steps which must be properly followed to avoid
breaking the laser tube. The included pictures show how to properly connect wires to the tube’s
electrodes and secure the connections.
REQUIRED PARTS AND TOOLS:
• 45W REPLACEMENT TUBE
• 2.5 MM HEX WRENCH
FRAGILE GLASS!
Pulling on the tube wires will break
your laser tube at the neck. The water connections are very
fragile, DO NOT pull or force the connection tubes— gently
work the tubes off of the connectors.
SHOCK WARNING! The capacitors in the power supply
retain power even after turning the laser off. To ensure your
safety, turn off the laser, remove the power cord and wait at
least 1 hour before accessing the power supply.
Stage 5: Automatic Focus Lens Alignment
The focal lens does not require alignment; it automatically detects surface distance
via the Intel 3D Camera.
Focal Lens
Manual Focus
Not Required
Intel 3D Camera
The focal lens is located torwards the bottom of the laser head assembly.
The default lens for Muse is 2.0
The following lenses are compatible with Muse 3D:
1.0, 2.0, 2.5 and 5.0
37
Technical Support is available from 8am to 5pm (PST) M - F at support@fslaser.com.
SECTION VIII. HARDWARE & MAINTENANCE
With a little care and maintenance, your Muse 3D Laser Cutter will remain clean and continue to run
at top efficiency for years to come. Be aware of all safety and maintenance issues with your machine
by following all the safety instructions in this manual.
Replacing the Laser Tube
This section provides procedures and a walkthrough to replace the laser tube on your Muse 3D.
Although it should last for hundreds of projects, the laser tube is considered a consumable and will
eventually need to be replaced. Please carefully read all instructions before beginning the
replacement procedure as there are several critical steps which must be properly followed to avoid
breaking the laser tube. The included pictures show how to properly connect wires to the tube’s
electrodes and secure the connections.
REQUIRED PARTS AND TOOLS:
• 45W REPLACEMENT TUBE
• 2.5 MM HEX WRENCH
FRAGILE GLASS!
Pulling on the tube wires will break
your laser tube at the neck. The water connections are very
fragile, DO NOT pull or force the connection tubes— gently
work the tubes off of the connectors.
SHOCK WARNING! The capacitors in the power supply
retain power even after turning the laser off. To ensure your
safety, turn off the laser, remove the power cord and wait at
least 1 hour before accessing the power supply.
Stage 5: Automatic Focus Lens Alignment
The focal lens does not require alignment; it automatically detects surface distance
via the Intel 3D Camera.
Focal Lens
Manual Focus
Not Required
Intel 3D Camera
The focal lens is located torwards the bottom of the laser head assembly.
The default lens for Muse is 2.0
The following lenses are compatible with Muse 3D:
1.0, 2.0, 2.5 and 5.0
37
Section IV. Tests & Adjustments
Focus Lens
Focus Lens & Camera
The focal lens does not require alignment; it automatically detects surface distance via the Intel 3D Camera.
The focal lens is located towards the bottom of the laser head assembly.
The default lens for the Muse is 2.0.
The following lenses are compatible with Muse 3D: 1.0, 2.0, 2.5, and 5.0