Using Your Coolbox
1.Add Distilled Water: Unscrew water cap. Fill tank with distilled water (approx. 1250 ml). Put
cap back on and tighten.
2.Power On Coolbox: Flip the red power switch to the “On” position. Remember to always run your
Coolbox when the laser is operating.
Appendix A. Coolbox
Using Your Coolbox & Map
Full Spectrum Laser provides the best customer support in the industry. Contact us if you have any questions or issues with
your Muse Laser Cutter. We can also offer convenient purchasing of accessory upgrades and replacement of consumable
items. Refer to this sheet for all your customer support and reordering needs.
Support
Monday-Friday 8am to 5pm (PMT)
support@fslaser.com
702.802.3103
Sales
Monday-Friday 8am to 5pm (PMT)
sales@fslaser.com
702.802.3101
Tutorials also available on
Complete user manual available : http://fslaser.com
Laser 101
Tons of assets to help you along the way.
http://laser101.fslaser.com
Quick-Start Guide
A. Connect the Exhaust System
1. Mount the exhaust cowling to the Muse exhaust port.
2. Attach with 4” ducting to ange side of exhaust fan, then the second
ducting to the exit port of the exhaust fan.
3. Ventilate the ducting outside through a window or exhaust port.
4. If using a fume extractor, you can attach the ducting from Muse directly to
the fume extractor.
C. Assemble the Air Compressor
1. Remove the air compressor from its packaging. Gently screw on the push
tting to air compressor.
2. Push one end of the black air inlet hose into the air compressor push tting
until it is snug.
3. Insert the other end of the black air inlet hose into the “air inlet” nozzle in
the back of laser cutter via the barbed air connect tting.
D. Connect Power
1. The power cord plugs into a “C14” power receptacle located on the back
side of the machine.
2. Follow the diagram and connect all power connections to a central power
bank and then plug the power strip into an appropriate wall outlet.
E. Connect Ethernet Cable
1. Locate and remove the included Ethernet cable from its packaging.
2. Plug in the Ethernet cable into the Ethernet slot on your Muse.
3. Plug the other end of the Ethernet cable into your computer’s Ethernet slot.
4. Connect Via Router (Recommended): Router connectivity is more
reliable than directly connecting via Ethernet and should be the primary
way of connecting.
B. Assemble Cool Box / Water System
1. Using the large rubber tubing included, connect the water-out on the
Cool Box to the water-in on the Muse. Do the same from the water-in
on the Cool Box to the water-out on the Muse. Water should ow out of
Coolbox into Laser Tube then back to the Cool Box. Double check these
connections.
2. Using the smaller black rubber tubing, connect the air-out connection on
the Cool Box to the air assist port on the back of the Muse.
3. Assemble & attach exhaust fan and ange to back of the Muse.
4. Plug power cable into back of Cool Box
5. Connect the black 4-prong cable from Cool Box to your Muse Laser system.
This cable runs from the back of your Cool Box to the back of your Muse.
If do not have a Cool Box for your Muse please refer to instructions
Your Muse will require some minor assembly of the accessory systems, such as the water system. This process should take less than an hour to complete.
Your Muse User Manual has complete assembly instructions.
Muse Assembly
Water Inlet
Water Outlet
Power On/O
Power Supply
Air Inlet
Coolbox Control
Pause/Stop Button
Exhaust Fan / Flange
Cooling Vents
Ethernet Port
USB Port
Exhaust Control
Particle Filter / Exhaust
Water Tubing
Air Tubing
Power Cords
Machine Control
Software Connection
Back ViewSide View
ATTENTION: Cut zip all zip-ties (2) before assembling your Muse.
Power 110V
Computer
Network / Router
Ethernet cable
Booster Fan
(optional)
Particle Filter
(optional)
Window / Door
Fume Extractor
Outside
Water Out
Water In
OR
Cool Box / Water
Chiller / Bucket
Some users may have
purchased as “industrial
chiller” Please refer to
your user manual for
setup instructions
Ducting
Laser Tubes
45W Laser Tube
Focus Lenses
1.5” Lens, 2” Lens
2.5” Lens, 5” Lens
Rotary / Riser Attachments
Friction Rotor
Muse Riser
Water Assist
Active Water Chiller
Air Assist
Air Compressor
Extractors & Particle Filters
Small, Medium and Large Available
Exhaust Fan
Booster Fan
Filter Replacements
Small, Medium and Large Available
Contact sales department to order • 702.802.3101 • sales@fslaser.com
Accessories & Upgrades
40/45 Watt Laser Tube
X-Gantry
Focus Head
Camera
Touchscreen
20 x 12 Engraving Area
Honeycomb Tray
Top View
Do not use
exhaust control
Water Out
Water In
Fill with Distilled Water
Fan Flange
Exhaust Fan
Full Spectrum Laser provides the best customer support in the industry. Contact us if you have any questions or issues with
your Muse Laser Cutter. We can also offer convenient purchasing of accessory upgrades and replacement of consumable
items. Refer to this sheet for all your customer support and reordering needs.
Support
Monday-Friday 8am to 5pm (PMT)
support@fslaser.com
702.802.3103
Sales
Monday-Friday 8am to 5pm (PMT)
sales@fslaser.com
702.802.3101
Tutorials also available on
Complete user manual available : http://fslaser.com
Laser 101
Tons of assets to help you along the way.
http://laser101.fslaser.com
Quick-Start Guide
A. Connect the Exhaust System
1. Mount the exhaust cowling to the Muse exhaust port.
2. Attach with 4” ducting to ange side of exhaust fan, then the second
ducting to the exit port of the exhaust fan.
3. Ventilate the ducting outside through a window or exhaust port.
4. If using a fume extractor, you can attach the ducting from Muse directly to
the fume extractor.
C. Assemble the Air Compressor
1. Remove the air compressor from its packaging. Gently screw on the push
tting to air compressor.
2. Push one end of the black air inlet hose into the air compressor push tting
until it is snug.
3. Insert the other end of the black air inlet hose into the “air inlet” nozzle in
the back of laser cutter via the barbed air connect tting.
D. Connect Power
1. The power cord plugs into a “C14” power receptacle located on the back
side of the machine.
2. Follow the diagram and connect all power connections to a central power
bank and then plug the power strip into an appropriate wall outlet.
E. Connect Ethernet Cable
1. Locate and remove the included Ethernet cable from its packaging.
2. Plug in the Ethernet cable into the Ethernet slot on your Muse.
3. Plug the other end of the Ethernet cable into your computer’s Ethernet slot.
4. Connect Via Router (Recommended): Router connectivity is more
reliable than directly connecting via Ethernet and should be the primary
way of connecting.
B. Assemble Cool Box / Water System
1. Using the large rubber tubing included, connect the water-out on the
Cool Box to the water-in on the Muse. Do the same from the water-in
on the Cool Box to the water-out on the Muse. Water should ow out of
Coolbox into Laser Tube then back to the Cool Box. Double check these
connections.
2. Using the smaller black rubber tubing, connect the air-out connection on
the Cool Box to the air assist port on the back of the Muse.
3. Assemble & attach exhaust fan and ange to back of the Muse.
4. Plug power cable into back of Cool Box
5. Connect the black 4-prong cable from Cool Box to your Muse Laser system.
This cable runs from the back of your Cool Box to the back of your Muse.
If do not have a Cool Box for your Muse please refer to instructions
Your Muse will require some minor assembly of the accessory systems, such as the water system. This process should take less than an hour to complete.
Your Muse User Manual has complete assembly instructions.
Muse Assembly
Water Inlet
Water Outlet
Power On/O
Power Supply
Air Inlet
Coolbox Control
Pause/Stop Button
Exhaust Fan / Flange
Cooling Vents
Ethernet Port
USB Port
Exhaust Control
Particle Filter / Exhaust
Water Tubing
Air Tubing
Power Cords
Machine Control
Software Connection
Back ViewSide View
ATTENTION: Cut zip all zip-ties (2) before assembling your Muse.
Power 110V
Computer
Network / Router
Ethernet cable
Booster Fan
(optional)
Particle Filter
(optional)
Window / Door
Fume Extractor
Outside
Water Out
Water In
OR
Cool Box / Water
Chiller / Bucket
Some users may have
purchased as “industrial
chiller” Please refer to
your user manual for
setup instructions
Ducting
Laser Tubes
45W Laser Tube
Focus Lenses
1.5” Lens, 2” Lens
2.5” Lens, 5” Lens
Rotary / Riser Attachments
Friction Rotor
Muse Riser
Water Assist
Active Water Chiller
Air Assist
Air Compressor
Extractors & Particle Filters
Small, Medium and Large Available
Exhaust Fan
Booster Fan
Filter Replacements
Small, Medium and Large Available
Contact sales department to order • 702.802.3101 • sales@fslaser.com
Accessories & Upgrades
40/45 Watt Laser Tube
X-Gantry
Focus Head
Camera
Touchscreen
20 x 12 Engraving Area
Honeycomb Tray
Top View
Do not use
exhaust control
Water Out
Water In
Fill with Distilled Water
Fan Flange
Exhaust Fan