3-2
CAUTION: Ensure that the settings to be loaded are compatible with this NavNet unit.
Improper setting will damage the equipment.
7. The screen for set up of units of measurement appears.
RANGE UNIT nm, kt
DEPTH UNIT ft
TEMPERATURE UNIT qF
WIND UNIT kt
LOCAL TIME OFFSET +00:00
Installation wizard, units of measurement
8. Choose an item and then press the EDIT soft key. One of the following windows
appears.
RANGE/SPEED UNIT
{
nm, kt
~
km, km/h
{
sm, mph
{
nm & yd, kt
{
nm & m, kt
{
km & m, km/h
{
sm & yd, mph
DEPTH UNIT
{
m
~
ft
{
fa
{
PB
TEMPERATURE UNIT
{ q
C
~ q
F
WIND SPEED UNIT
{
kt
~
km/h
{
MPH
{
m/s
LOCAL TIME OFFSET
+
0:00
9. Choose unit of measurement desired and then press the ENTER soft key. LOCAL TIME
OFFSET allows you to use local time (instead of UTC time). Set the time difference
between local time and UTC time.
10. After you have chosen units of measurement, press the NEXT soft key, and the
NETWORK SETUP menu appears.
DEVICE NUMBER 1
(HOST NAME NAVNET-1)
(IP ADDRESS 172.031.003.003)
RADAR SOURCE 1
SOUNDER SOURCE ETRO
AUX SOURCE AUX1
Installation wizard, network setup