EasyManua.ls Logo

Furuno DRS2D - Wiring for DRS2 D;4 D;4 A;6 A;12 A with PSU-012; Wiring for DRS2 D;4 D with PSU-017

Furuno DRS2D
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Wiring for DRS2D/4D/4A/6A/12A with PSU-012
Wiring for DRS2D/4D with PSU-017
Radar Sensor
DRS4A/DRS6A/DRS12A
NMEA2000
Equipment
: Standard Supply
: Optional Supply
: Local Supply
NMEA2000
Equipment
Radar Sensor
DRS2D/DRS4D
To Multi Function Display BlackBox
MFDBB/TZTBB or Multi Function Display
MFD8/12, TZT9/14
Two-way cable
MOD-ASW0001
(10/15/20/30 m)
NMEA2000 cable
M12-05BFFM (ø6) or
CB-05BFFM (ø10)
NMEA2000 cable
M12-05BFFM (ø6) or
CB-05BFFM (ø10)
LAN cable
MOD-WPAS0001-030+
Power cable
VL3P-VV-S2X2C-AA050
(supplied with PSU-012)
12-24 VDC
To ship's ground
Ground wire
(Local supply, IV-2sq)
Power Supply Unit
PSU-012
(Power)
(LAN)
3 m: supplied with
MFD8/12/BB, TZT9/14/BB
Power cable*
(The input voltage range at the edge of the power cable:
10.8 to 31.2 VDC.)
*The power cable is supplied with attached to the unit. When connecting the power cable to ship’s mains,
pass through the disconnecting device (breaker, etc.).
Radar Sensor
DRS2D/DRS4D
: Standard Supply
: Optional Supply
: Local Supply
NMEA2000
Equipment
NMEA2000 cable
M12-05BFFM (ø6) or
CB-05BFFM (ø10)
LAN cable
Two-way cable
MOD-ASW0001
(10/15/20/30 m)
12-24 VDC
Ground wire
(Local supply, IV-2sq)
To ship's ground
Power Supply Unit
PSU-017
To Multi Function Display BlackBox
TZTBB or Multi Function Display
TZT9/14