3. Insert wires of cable M12-05BFFM (φ6) or CB-05BFFM (φ10) to the NMEA connector inside the
radar sensor, consulting the label on the connector for location. As for shield, use the cable
clamp shown below.
Cable M12-05BFFM (φ6) CB-05BFFM (φ10)
Clamp
Use the clamp pre-attached inside the radar
sensor.
Use the clamp supplied with the optional gasket
(Type: OP03-203,
Code No.: 001-025-290)
15
5
CB-05BFFM cable
370
CB-05BFFM cable
20
65
15 (Area fastened with the cable clamp)
Wind vinyl tape.
(supplied)
Fabrication of CB-05BFFM cable
Fasten the cable tie (supplied) within
15 mm from the end of vinyl sheath.
Shield
Zoom up
Attach the cable clamp
using this screw for CB-
05BFFM cable. (Face
projecting part down.)
Cable clamp
Location of the cable clamp