12
Setting procedure
1. Turn off the main display unit. Turn on the power while pressing and holding down the
[Distance/Keel Clearance] selector. "1" indicates system setting no. 1 at the center of the display.
DOPPLER SONAR
DS-50
MODE
Keel Clearance
m/s
fa
DIMMER
NM
kn
ft
D
istance
AL
G
W
A
S
FURUNOFURUNO
"1" appears.
Setting
(The number corresponds to that on
the table on page 11.)
Hinged cover
2. Press or to select system setting number to be changed.
3. Press W or X to change setting.
4. Press or to verify the data entered.
5. Turn off the power, and the new settings are entered in memory.