EasyManua.ls Logo

Furuno ECDIS FMD-3100 - Wiring

Furuno ECDIS FMD-3100
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-1
2. WIRING
The illustration on this page shows the general connection between the FMD-3100
and external equipment. For detailed information, see the interconnection diagram at
the back of this manual. Many of the cables mentioned are JIS (Japan Industry Stan-
dard) cables. If not available locally, use the equivalent. See the cable guide in the Ap-
pendix for how to select equivalent cables.
Intelligent HUB
HUB-3000
DTI-C5E350 VCV,
10/20/30 m
100-230 VAC
ALARM SYSTEM
DPYC-1.5
PR-240: DPYC-1.5
DPYC-1.5
Intelligent HUB
HUB-3000*
DTI-C5E350 VCV,
10/20/30 m
DPYC-1.5
100-230 VAC
STP (CAT5) cable
or
Sensor Adapter
MC-3000S (Serial IN/OUT)
- MC-3020D (Digital IN)
- MC-3030D (Digital OUT)
Sensor Adapter
MC1.5-W-L cable,
0.6/1/2/3 m
24 VDC
AC/DC Power
Supply Unit
PR-240/241
100-115/200-230 VAC
Sensor
Adapter
Panel
Computer
Unit
PCU-3010
Trackball Control Unit
RCU-030
USB cable, 1.5 m
USB cable, 2 m
Keyboard
5139U BLACK or SKB-E3U
Radar Connection Box
RCB-002
MOD-Z072, 2/5/10 m
MJ-A10SPF0020A,
5/10/20/30 m
MJ-A10SPF0020A,
5/10/20/30 m
External Radar
External Radar
External
Monitor
or
VDR
MJ-A10SPF, 5 m
100-230 VAC 24 VDC
DPYC-1.5
AIS
TTYCSLA-4
GYRO
TTYCSLA-4
GPS
TTYCSLA-1Q
LOG
TTYCSLA-1Q
To Ext. Monitor*, VDR*:
3COX-2P-6C 5 m
* Use DP-VGA adapter
(supplied) to connect.
Select AC or DC power supply
PR-241: TPYC-1.5
DPYC-1.5
FR-FTPC-CY,
10/20/30 m
*: For IEC 61162-450 Ed. 1 complying network,
Switching Hub HUB-100 may be used.