2. WIRING
2-13
2.2 Sensor Adapters (Optional)
Maximum eight MC-3000S can be connected to a sensor network (for the redundant
connection: 16). The MC-3000S (serial input/output, IEC61162-2/1, 4ch) can connect
max. 10 sensor adapters using the MC1.5-W cables.
To connect the lines to the connector on the sensor adapter, use the rod terminal (fer-
rule type, supplied) to maintain performance. This fabrication requires the optional
crimping tool (type: CRIMPFOX 10S).
For the relations between the connectors and rod terminals, see page AP-2. Also, the
stickers attached on the reverse side of the covers show the detailed connections.
Use the MC1.5-W cable between the sensor adapters. Attach the cables to the appli-
cable pins.
Note: The total length of the MC1.5-W cables should be less than 6 m to prevent mal-
function.
Pin No. Cable color Signal
1 Red 24V_OUT or 24V_IN
2 Black 24V_GND
3 White MODBUS-A
4 Blue MODBUS-B
5Gray GND
Rod terminal (ferrule type):
After attaching the rod terminal, use the optional
crimping tool CRIMPFOX 10S to crimp.
L
0.5 to 1 mm
How to attach ferrule-type lug
Core
Vinyl sheath
Rod terminal (ferrule type):
The core must protrude 0.5 to 1 mm
past the rod terminal.
Ferrule-type lug Length of ā€œLā€
AI 1.5-6 BK (BLK)
AI 0.34-6 TQ (BLU)
AI 0.75-6 GY (GREY)
AI 1-6 RD (RED)
6 mm
AI 0.14-8 GY(GREY) 8 mm