3. INPUT/OUTPUT SIGNAL
3.1 Inputs from Sensors
There are three input ports (SENSOR 1, 2 and 3) which are based on the IEC
61162-1/2. The protocol is RS422. If there is no HDT signal from a gyrocompass,
connect the gyrocompass signal (Synchro or step signal) to the “AD-10 IN” port
(D-sub 9 pins) of the transponder unit via the FURUNO A/D Converter AD-100 (See
page 16).
1TD3-A
2TD3-B
3GNDISO
4RD3-A
5RD3-B
6GNDISO
7TD2-A
8TD2-B
9GNDISO
10RD2-A
11RD2-B
12GNDISO
13TD1-A
14TD1-B
15GNDISO
16RD1-A
17RD1-B
18GNDISO
19TD5-A
20TD5-B
21GND
22RD5-A
23RD5-B
24GND
TB1inthejunctionbox
GPSnavigatoronly
TTYCS-1Q
IsolatedGND
HeadingSignal(HDT)
TTYCS-1Q
IsolatedGND
SpeedSignal(SOG)
TTYCS-1Q
IsolatedGND
TTYCS-1Q
GND0V
DGPS
Beacon
Receiver
SENSOR3(EXTGPSIN)
SENSOR2
SENSOR1