14
Range, Gain and Mode knobs
Operate the controls. The RANG and MODE control setting indications should be the same
as actual control settings. The GAIN control setting indication should be among 0 to 235-
255.
If some abnormal condition is obtained by controlling the RANGE and MODE knobs, the
PANEL or MAIN board ( Gate array U10 ) is suspected to be defective.
If some abnormal condition is obtained by controlling the GAIN knob, the PANEL or U1
(CPU) of MAIN board is suspected to be defective.
Test Pattern
Self-test is performed by the following key operation.
1. Turn on the power while pressing any key.
2. Press the BRILL key three times. Press the BRILL key again to change the test pattern
as below.
Figure 3.2 Test pattern
The " Full Screen BLACK/WHITE " checks the pixels of LCD.
The eight color gradation checks the R.G.B signals of LCD interface circuit on the MAIN board.
Full Screen
BLACK
Full Screen
WHITE
B
L
A
C
K
R
E
D
G
R
E
E
N
B
L
U
E
Y
E
L
L
O
W
P
U
R
P
L
E
A
Q
U
A
W
H
I
T
E