2. WIRING
2-20
2.6 Connection of Digitizer and LCD Displays to
Processor Unit
The brilliance of ECDIS and Conning Displays (MU-201CE/MU-231CE/MU-190/MU-231)
can be adjusted at EC-1000C by connecting to COM1 port as below. Also, COM1 port is
used for connection of Digitizer (CALCOMP Drawing Board III).
MU-201CE/231CE
MU-190/231
ECDIS Display
Digitizer
EC-1000C
DVI 5 m (standard supply)/10 m (option)
RGB 10/30 m (option)
DVI 5 m (standard supply)/
10 m (option)
RGB 10/30 m (option)
Serial
signal
Serial
signal
DSUB9P-DSUB9P-L5M*DSUB9P-DSUB9P-L5M*
DSUB9P3-B
(supplied with
EC-1000C-C)
DSUB9P3-A
(supplied with all type of EC-1000C)
D-sub 9 pin
D-sub 9 pin
COM1
Cable supplied
with Digitizer
*10 m/30 m: option
MU-201CE/231CE
MU-190/231
ECDIS Display
2.7 Power Cabling to ECDIS
ECDIS is powered by 100-230 VAC power. See figure below for cabling.
ECDIS
L
NN
L
IEC Socet
100-230VAC