EasyManua.ls Logo

Furuno FEA-2107-BB - 2.3 Positioning

Furuno FEA-2107-BB
168 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
v
Multi-workstation configuration
In the multiple workstation configuration, there can be two workstations connected together
by a Local Area Network (LAN). In this configuration, one workstation is used as the “sensor
source” for navigation sensors and the other workstation(s) are using the sensor source
workstation to communicate with sensors, receiving and transmitting data from/to
workstation via the LAN. In the multi-workstation configuration (two fully redundant
navigation workstations), where navigation sensors are connected to two workstations, the
sensor source may be changed and still receive and transmit information from/to the system
and to/from navigation sensors. User-defined workstation is responsible for sensors.
ECDIS Monitor Conning Monitor
ECDIS PROCESSOR
EC1000C
LAN-ADAPTER
EC-1010
LAN-ADAPTER
EC-1010
B-ADAPTER
EC-1020
ARPA RADARS
POSITION-FIXING EQUIPMENT
TRACK PILOT
LOG/DUAL AXIS LOG
AIS
GYRO COMPASS
POSITION EQUIPMENT
ENGINE CONTROL
ECHOSOUNDER
WIND SENSOR
WATER TEMP. METER
AMWSS
(Alarm Monitoring
Watch Safety System)
GYRO COMPASS
(SYNCHRO, STEPPER)
LOG (200P/NM)
ANALOG INPUT (8 CHANNELS)
ANALOG OUTPUT (ECDIS, 8 CHANNEL)
100-230 VAC
100-230 VAC
100-230 VAC
CALCOMP
DRAWING -
BOARD III
DIGITIZER
PRINTER
HUB-
100
100-230 VAC
24 VDC
24 VDC
24 VDC
RADAR OVERLAY PCB
ECDIS PROCESSOR
EC1000C
LAN ADAPTER
EC-1010
LAN ADAPTER
EC-1010
B ADAPTER
EC-1020
ARPA RADARS
POSITION-FIXING EQUIPMENT
TRACK PILOT
LOG/DUAL AXIS LOG
AIS
GYRO COMPASS
POSITION EQUIPMENT
ENGINE CONTROL
ECHOSOUNDER
WIND SENSOR
WATER TEMP. METER
AMWSS
(Alarm Monitoring
Watch Safety System)
GYRO COMPASS
(SYNCHRO, STEPPER)
LOG (200P/NM)
ANALOG INPUT (8 CHANNEL)
ANALOG OUTPUT (8 CHANNEL)
100-230 VAC
PRINTER
OPTION
EXTERNAL
DEVICE
HUB-
100
100-230 VAC
24 VDC
24 VDC
24 VDC
RADAR OVERLAY PCB
ECDIS Monitor
100-230 VAC
RADAR 1 (VIDEO, HL, AZ)
RADAR
SWITCH
RADAR 2 (VIDEO, HL, AZ)
RADAR 1 (VIDEO, HL, AZ)
RADAR
SWITCH
RADAR 2 (VIDEO, HL, AZ)
Control Unit
RCU-018
or
TB Control Unit
RCU-015FEA
Remote Control Unit
RCU-016
Control Head
RCU-018
or
TB Control Unit
RCU-015FEA
Remote Control Unit
RCU-016
(WORKSTATION)
(WORKSTATION)
Rectifier
PR-62
100/230 VAC
Rectifier
PR-62
100/230 VAC
Rectifier
PR-62
100/230 VAC
Rectifier
PR-62
100/230 VAC
Rectifier
PR-62
100/230 VAC
Rectifier
PR-62
100/230 VAC
(USB)
ALARM OUTPUT
(ECDIS SYSTEM FAIL)
ALARM OUTPUT
(ECDIS SYSTEM FAIL)
(USB)
DVI or RGB
DVI or RGB
MU-201CE (FEA-2107)
MU-190 (FEA-2107-D)
MU-231CE (FEA-2807)
MU-231 (FEA-2807-D)
MU-201CE (FEA-2107)
MU-190 (FEA-2107-D)
MU-231CE (FEA-2807)
MU-231 (FEA-2807-D)
MU-201CE (FEA-2107)
MU-190 (FEA-2107-D)
MU-231CE (FEA-2807)
MU-231 (FEA-2807-D)

Other manuals for Furuno FEA-2107-BB

Related product manuals