5.4 Block Description
5-26
OVER CURRENT PROTECTION ON U1
This protection functions to stop the output when U1 output current increases more than
14 A and also functions as an automatic recovery function.
LOW VOLTAGE OUTPUT PROTECTION ON U1
This protection functions to stop the output when the voltage is over +17 VDC.
Turn off the power temporarily when this happens.
OVER HEATING PROTECTION ON U1
This protection functions to stop the output when the temperature on module plate
reaches over 100 degrees and also functions as an automatic recovery function.