AP2.2 NBDP test
AP2-3
AP2.2 NBDP test
To test the NBDP, receive Maritime Safety Information and make a ARQ communication.
AP2.2.1 Receiving MSI (Maritime safety Information)
To receive the MSI, follow the steps below.
1. Check that the receiving mode is set to “AUTO” on the NBDP terminal.
Menu operation: [F3][6]: Manual Reception
2. Check that Print appears on the display, showing the terminal is in Print mode. If not,
set Real Time Printing to ON.
Menu operation: [F1][6]: Real Time Printing
3. Set the RF gain to the maximum.
4. Enter the receiving frequency from the NBDP terminal.
Menu operation: [F3][9]: Set Frequency
“Occupied (NBDP)” appears in the RT display.
5. The message is automatically received and printed at the scheduled time.
6. If the message is received normally, the NBDP works normally.
Note: “*” mark in the received message means the letter cannot be reproduced.