95
→ GO to TABLE OF CONTENTS
Telemetry: Receiver [Battery]
Displaying data from t he 
receiver battery voltage
In this screen, the battery voltage of a receiver is 
displayed.
If it becomes higher or lower than the settin, an 
alarm and/or vibration will alert you.
*It cannot be used in FASST mode and S-FHSS mode.
*Only receiver voltage and EXT voltage can be used in 
FASSTest12CH mode.
*The FASSTest18CH /T-FHSS mode can use all the telemetry 
functions.
Alarm set 
1. Tap Alarm and choose from Buzzer, Voice, 
and Inhibit.
2. Choose "Inhibit" for Vibrator if not using the 
vibrator alarm. If using vibrator, choose one 
of the three types.
3. Tap to the Limit [4.0 V] item. 
4. Adjust the rate using the "▼▼" "▼" "▲" "▲▲" 
buttons.
  Initial value: 4.0 V
  Adjustment range: 0.0 V~100.0 V
*When the screen is tapped for one second, the rate is reset 
to the initial value.
5. To terminate the input and return to the 
original state, push the HOME/EXIT button.
Receiver battery 
voltage 
Sets the voltage on 
which the alarm 
operates. 
↓The "down" arrow 
will indicate that an 
alarm will sound when 
the voltage drops to 
below the setting.
Alarm is chosen from 
Buzzer, Voice, and 
Inhibit.
Allows Speech to be 
turned ON or OFF.
● Tap the [Receiver] button in the Telemetry screen 
to call the setup screen shown below.
Max. and min. values 
since the power 
was turned ON will 
display.
Type 1
Type 2
Type 3
"Vibrator" type
If the following types are selected, the transmitter 
will vibrate during the warning.
●Return to 
Linkage menu