Pr.31 Heavy Door Quick Stop on Reverse
Unit: 0.1 A
Default: 2.0A
Range: 0~180 %rated
This parameter determines the level of the DC braking Current output to the motor during stopping.
Pr.32 Heavy Door Slow Start Open (SSO)
Unit: 0.1 Hz
Default: 5.0 Hz
Range: 0 ~ 400.0 Hz
Pr.33 Heavy Door High Speed Open (HSO)
Unit: 0.1 Hz
Default: 45.0 Hz
Range: 0 ~ 400.0 Hz
Pr.34 Heavy Door Medium Speed Open (MSO)
Unit: 0.1 Hz
Default: 20.0 Hz
Range: 0 ~ 400.0 Hz
Pr.35 Heavy Door Final Speed Open (FSO)
Unit: 0.1 Hz
Default: 5.0 Hz
Range: 0 ~ 400.0 Hz
Pr.36 Heavy Door Open Acceleration Time
Unit: 0.1 Sec
Default: 4.0 Sec
Range: 0~400.0 Sec
The Acceleration time is used to determine the time required for the AC drive to ramp from 0 Hz to
its reference frequency (Pr.50).
Pr.37 Heavy Door Open Deceleration Time
Unit: 0.1 Sec
Default: 10.0 Sec
Range: 0 ~ 400.0 Sec
The Deceleration time is used to determine the time required for the AC drive to decelerate from
the reference frequency (Pr.50) down to 0 Hz.
Pr.38 Heavy Door Open Slow Speed Torque
Unit: 0.1 %
Default: 0 %
Range: 0 ~ 30 %
Increase the setting when motor torque in low speed range is insufficient.
G.A.L. Manufacturing Corporation December, 2007