Disable the keypad
You may find it necessary to lock the front panel keypad to prevent
any unauthorised changes to the settings to the RC120. To disable
the keypad, type in the following command:
KBd,c
Where:
d = 0 to enable the keypad.
d = 1 to disable the keypad, but allow the unlock code to be
entered on the keypad.
d = 2 to disable the keypad and disallow the unlock code to be
entered on the keypad.
c = the unlock code, which must be a number from 0 to 255.
You can still access the RC120’s settings using Ethernet commands
and through its web page. The settings of this command are
restored after a power cycle.
10.4 Command summary
Command Example Effect
AW AW Save changes.
CL CL Clear configuration.
GT GT1 Enable Ethernet messages.
GR GR Clear any error conditions.
EY EY65,66 Set webpage password to 'AB'.
VR VR Read the firmware version.
VL VL1,0,0.5 Set the light to 0.5A.
RS RS1,65 Set the unit to 65% brightness
continuously.
RW RW1,50 Set the unit ot 50%, switch mode.
RT RT1,3,4,50 Set the unit to 3ms pulses, delayed by
4ms, at 50% brightness.
RE RE1,6 Set the unit to ignore lighting errors and
make its trigger input active low.
TT TT1,100 Set the internal trigger to operate every
100ms.