EasyManua.ls Logo

GARDASOFT RC100 - Event Codes

Default Icon
49 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RC1xx - User Manual
11.3 Event codes
On receipt of a GT1 command, event messages are sent by the RC120
over its Ethernet link when a light is connected or an error occurs. The
message format is:
Evt1,<event code>
Some event codes are displayed on the RC1xx’s front panel; these are
shown in red.
Event
number
Reason
1 to 127 An error has occurred. See Section 11.4, Error codes.
128 A light has been connected and is working.
129
A light has been connected but does not have a current
or voltage rating.
130 FAT
An over temperature error has occurred.
131 FAC
A over current error has occurred.
132
An error has occurred while autosensing the rating of a
light.
138 SafePower trainup has completed.
139 SafePower trainup has failed or been cancelled.
140
In switched mode, the light has been turned off because
the duty cycle is too high.
41

Other manuals for GARDASOFT RC100