RC1xx - User Manual
11 RC1xx reference information
This section of the user manual contains information about the RC1xxT’s
specification, ratings and restrictions, and event and error codes.
11.1 Specifications and ratings
RC100 RC120
User interface Pushbutton
Ethernet and
pushbutton
Output channel One constant current output with SafeSense
Output current
Up to 1.0Acontinuous
and 1.0Apulsed
Up to 1.2Acontinuous
and 2.0Apulsed
Output voltage 0V to 32V
Pulsed output
average power
Max 25W
Trigger input
Smart input compatible with 3V-24V, TTL, NPN,
and PNP.
Input Impedance (nom) 8kohms
Pulse timing From 100µs to 100ms in steps of 100µs
Delay from
trigger to pulse
Maximum 10µs fixed latency plus user adjustable
steps of 100µs to a maximum of 100ms
Timing
repeatability
(delay)
±5µs (delay + pulse up to 60ms)
Otherwise ±50µs
Switch mode
latency
Maximum 100µs
Trigger rate Maximum 100Hz
Supply voltage
Regulated 24VDC ±10%
A SELV power supply is required
Dimensions
(excluding
DIN fixing)
120mm long x 35mm wide x 101mm high
Weight 0.3kg
Mounting DINrail mount
38