RC1xx - User Manual
10.3.3 General commands
Any changes you make using Ethernet commands are not saved
permanently until you send the AW command.
Report the RC120 firmware version
This command returns the firmware version ruining on the RC120.
For example, typing:
VR returns
RC120 (HW101) V001
Set the rating of a light
This command sets the current or voltage rating of the light:
VL1,v,c
Where:
v = voltage rating (12 to 24)
c = current rating (10mA to 2A)
Note: If the light is current rated, set the voltage rating to 0; if it is
voltage rated, set the current rating to 0.
Set continuous mode
This command sets the output to continuous mode and allows the
brightness to be set:
RS1,s
Where:
s = brightness as a percentage (0 to 100)
Set pulse mode
This command sets the output to pulse on a trigger input:
RT1,p,d,s,r
Where:
p = pulse width in milliseconds (0.1 to 999)
d = delay from the trigger pulse in milliseconds (0 to 999)
s = brightness setting in percent (0 to 999)
r = retrigger delay in milliseconds (0.1 to 999). This parameter
is optional and if not set, the minimum allowed retrigger
time is set.
Note: An error message is returned if the brightness setting requires
a greater current than the maximum current output or if the
combination of pulsed width and brightness is not allowed under the
limitations of the unit.
— 32 —