RC1xx - User Manual
Set switched mode
This command sets the output to switched mode and allows the
brightness to be set:
RW1,s
Where:
s = brightness setting in percent (0 to 999).
Set the option flags
This command sets the flags for error detection, trigger sense, and
SafeSense:
RE1,m
Where the following code applies:
m
Error
detection
Trigger sense SafeSense
0 Enabled
+
Enabled
2 Disabled
+
Enabled
4 Enabled
–
Enabled
6 Disabled
–
Enabled
8 Enabled
+
Disabled
10 Disabled
+
Disabled
12 Enabled
–
Disabled
14 Disabled
–
Disabled
Set the internal trigger
These commands control the internal trigger. When set, the output
is triggered using an internal trigger signal. Type in:
TT0 to disable the internal trigger
TT1 to enable the internal trigger using the period last set
TT1,p to enable the internal trigger and set the period.
Where:
p = trigger period in milliseconds.
Note 1: The TT1 command does not disable external triggers.
Note 2: This setting can be saved to non-volatile memory using the
AW command.
Save the settings to memory
AW
This command saves the settings to non-volatile memory. If you
power cycle the RC120 before sending the AW command, all
changes are lost and the unit returns to the values set before the last
AW command.
— 33 —