Clear configuration
CL
This command clears the configuration and lighting ratings, and
turns the output off. The results of any VL, RS, RW, RU, RT, RE, RP,
TT, and AW commands are cleared.
Show configuration
This command shows the configuration of the RC120. Type in:
ST
A typical reply to this command might be:
CH1,MD0,S50.0,0.0,DL1.000ms,PU1.000ms,RT
0.0us,IP1,FL0,CS0.000A,RA0.000A
Where (see overleaf):
CH
Channel number; this is always
1.
MD
Mode: 0 = continuous, 1 = pulsed, 2 = switched.
S
Percentage brightness: 50.0 = 50%; the second part
is always 0.0.
DL
Pulse delay.
PU
Pulse width.
RT
Retrigger delay.
IP
Always return IP1.
FL
Flags set using the
RE1
command.
CS
Current rating of the light after being sensed
successfully by SafeSense.
RA
Configured voltage or current rating of the light set by
the
VL
command.
To view the status of the internal trigger, type in:
ST0
A typical reply to this command might be:
TM1,TP20.00ms
Where:
TM Trigger status. 1 = on, 0 = off
TP Trigger period