RC1xx - User Manual
Error
number
Reason
Err, 40, 41,
45,
FAC
Fatal error:
The unit is outputting more current than
expected.
Err 42,
SH
The output current is too high.
Err 43,
OP
The requested output current requires too high a
voltage.
Err 44,
FAt
Fatal error:
The
RC1xx
is too hot. The unit has a
thermal cut out which operates at approximately
65°C to 70°C depending on conditions.
Err 46 The channel output power is greatger than the
maximum allowed 30W.
Err 47,
FAS
Internal protection has activated to prevent too much
heat in the output driver