To set the error detection, press the
SEL
button
with
F E
displayed.
Or...
If you wish todisable the error detection, use
the
p
and
q
buttons to select
F-E
, and press
the
SEL
button.
Selected output is set up on the RT200.
9.6 Setting up pulsed operation
Pulsed operation allows you toset up the characteristics of the lighting
pulse irrespective of the trigger pulse duration. Press and hold SELfor one
second ,
CH1 is displayed. Use the p and q buttons to select the channel
you want to set up, and follow the keystrokesbelow:
The channel you want to set up is displayed.
Press the
SEL
button.
Use the
p
and
q
buttons to select
SPu
and
press the
SEL
button.
— 38 —
RTxxx LEDlighting controllers - User Manual
bri
is displayed. Press the
SEL
button to set the
lighting intensity.
Use the p and qbuttons to set the lighting
intensity from 1% to999%. Press the
SEL
button.
dEL is displayed. Press the SEL button to set
up the delay time as described in Section 9.7,
Setting time periods.
Press the SELbutton.
PUL is displayed. Press the SEL button to set
up the pulse width as described in Section 9.7,
Setting time periods.
Press the SEL button.
rEt is displayed. Press the SELbutton to set up
the retrigger time as described in Section 9.7,
Setting time periods.
Press the SELbutton.