14
GB
The factory settings are restored.
v Press Man.-key and Menu-key simultaneously for 3 seconds.
All the LCD symbols are displayed for 2 seconds and the
display moves to the normal display.
All the program data are set to zero.
The manual watering period is set to
00
::
3300
again.
The language, the time and the day of the week are retained.
If no entry is made during programming for a period of more than
60 seconds, the normal display reappears. In this case all changes
made up till now will be applied.
When a sensor installed in the Water Computer registers damp
(OFF), the programmed watering is not carried out. There must
be a 1 minute pause between programs.
6. Putting Your Water Computer out of Operation
1. Press Menu-key 3 times, select Prog
OOFFFF
with the rotary
button and confirm with the OK-key.
The watering program is not run.
2. Store your Water Computer in a dry place where it is protected
from frost.
The product must not be added to normal household waste. It
must be disposed of in line with local environmental regulations.
v Important: Make sure that the unit is disposed of via your
municipal recycling collection centre.
v Please return flat batteries to a GARDENA dealer or dispose
of them properly at your nearest recycling centre.
Only dispose of batteries when they are flat.
7. Maintenance
The filter
N
should be checked regularly and cleaned when
necessary.
1. Unscrew sleeve nut
I
of the Water Computer by hand
from the tap thread (do not use pliers).
2. If necessary unscrew the adaptor
H
.
3. Remove filter
N
from sleeve nut
I
and clean.
4. Fit the Water Computer again (see 4. Putting Your Water
Computer into Operation
Connecting Water Computer”
).
Reset:
Important information:
Storage /
Overwintering:
Disposal: