GTR 225/GNC 255 TSO Installation Manual 190-01182-02
Page 5-12 Rev. B
5.2.8.1.4 Flag
5.2.8.1.5 OBS
VOR OBS ROTOR C and H are a buffered 400 Hz output that is intended to drive the OBS rotors. VOR
OBS STATOR D and VOR OBS STATOR F are each phase and amplitude shifted version of the VOR
ROTOR C output. Each pair is intended to read one of the two windings of the indicator’s OBS stator.
5.2.8.1.6 VOR/LOC COMPOSITE
With a standard VOR test signal applied, VOR/LOC COMPOSITE OUT is 0.5 ± 0.1 Vrms into a 10 k
load. With a standard Localizer centering test signal applied, VOR/LOC COMPOSITE OUT is 0.350
±0.05 Vrms into a 10 k load.
5.2.8.1.7 GLIDESLOPE COMPOSITE
With a standard glideslope test signal applied, GLIDESLOPE COMPOSITE OUT is 0.350 +
0.05 Vrms
into a 10 k load.
5.2.8.1.8 NAV ILS ENERGIZE
The driver output voltage is not more than 1.0 V when sinking 20 mA. The maximum off state leakage
current with respect to GND is less than 10 A.
Pin Name Connector Pin I/O
VOR/LOC +FLAG P2002 3 Out
VOR/LOC -FLAG P2002 4 Out
GLIDESLOPE +FLAG P2002 32 Out
GLIDESLOPE -FLAG P2002 53 Out
Pin Name Connector Pin I/O
VOR OBS ROTOR C P2002 9 Out
VOR OBS ROTOR H (GND) P2002 10 --
VOR OBS STATOR D P2002 13 In
VOR OSB STATOR E (GND) P2002 11 --
VOR OBS STATOR F P2002 12 In
VOR OBS STATOR G (GND) P2002 14 --
Pin Name Connector Pin I/O
VOR/LOC COMPOSITE OUT P2002 8 Out
Pin Name Connector Pin I/O
GLIDESLOPE COMPOSITE OUT P2002 58 Out
Pin Name Connector Pin I/O
ILS ENERGIZE P2002 29 Out

Table of Contents