Page 26
LOCATIONS 56- 83 ARE ONLY USED WHEN REPORTING EVENTS TO A PAGER OR USING A SLOW FORMAT
SUCH AS 4+2. WHEN USING CONTACT ID OR SIA, THERE IS NO NEED TO PROGRAM THESE LOCATIONS.
LOCATION 56- RESTORE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical
data)
Location 56 contains the event code for any zone "Restore" for a 4+2 format. The digit programmed in this location will
be sent as the tens digit in place of the alarm event code. The zone ID will always be reported as the ones digit of
the zone number (i.e. 9 for zone 29). This location contains 8 segments. Any segment left as "0" will follow the
Segment 1 selection.
Segment 1: - Partition #1, "Restore Code".
Segment 2: - Partition #2, "Restore Code".
Segment 3: - Partition #3, "Restore Code".
Segment 4: - Partition #4, "Restore Code".
Segment 5: - Partition #5, "Restore Code".
Segment 6: - Partition #6, "Restore Code".
Segment 7: - Partition #7, "Restore Code".
Segment 8: - Partition #8, "Restore Code".
LOCATION 57 - BYPASS COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical
data)
Location 57 contains the event code for a zone "Bypass" for a 4+2 format. The digit programmed in this location will be
sent as the tens digit. The zone ID will always be reported as the ones digit of the zone number (i.e. 9 for zone
29). This location contains 8 segments. Any segment left as "0" will follow the Segment 1 selection.
Segment 1 - Partition #1, "Bypass Code".
Segment 2 - Partition #2, "Bypass Code".
Segment 3 - Partition #3, "Bypass Code".
Segment 4 - Partition #4, "Bypass Code".
Segment 5 - Partition #5, "Bypass Code".
Segment 6 - Partition #6, "Bypass Code".
Segment 7 - Partition #7, "Bypass Code".
Segment 8 - Partition #8, "Bypass Code".
LOCATION 58 - TAMPER COMMUNICATOR CODE, SLOW SPEED FORMATS (8 segments, numerical data)
Location 58 contains the event code for a zone "Tamper" for a 4+2 format. The digit programmed in this location will
be sent as the tens digit. The zone ID will always be reported as the zone number (i.e. 9 for zone 29). Any
segment left as "0" will follow the Segment 1 selection.
Segment 1 - Partition #1, "Tamper Code".
Segment 2 - Partition #2, "Tamper Code".
Segment 3 - Partition #3, "Tamper Code".
Segment 4 - Partition #4, "Tamper Code".
Segment 5 - Partition #5, "Tamper Code".
Segment 6 - Partition #6, "Tamper Code".
Segment 7 - Partition #7, "Tamper Code".
Segment 8 - Partition #8, "Tamper Code".

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Interlogix NX-8 - Security NetworX System and is the answer not in the manual?

GE Interlogix NX-8 - Security NetworX System Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320 power supply12 VDC Regulated 2 AMPS + Control
Loop Specifications IconLoop Specifications
standard loop resistance300 Ohms Maximum
2-wire smokes resistance30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
built-in siren driver2-tone (Temporal and Yelp)
LED keypad current draw130 mA max.
Weight and Dimensions IconWeight and Dimensions
metal enclosure dimensions11.25" Wide x 11.25" High x 3.50" Deep
shipping weight9 lbs.
LED keypad dimensions6.4" Wide x 4.0" High x 1.1" Deep
NX-148 LCD keypad dimensions6.4" Wide x 5.3" High x 1.0" Deep