Page 27
LOCATION 59 - TROUBLE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical
data )
Location 59 contains the event code for a zone "Trouble" for a 4+2 format. The digit programmed in this location will
be sent as the tens digit. The zone ID will always be reported as the zone number (i.e. 9 for zone 29). Any
segment left as "0" will follow the event code for partition 1.
Segment 1 - Partition #1, "Trouble Code".
Segment 2 - Partition #2, "Trouble Code".
Segment 3 - Partition #3, "Trouble Code".
Segment 4 - Partition #4, "Trouble Code".
Segment 5 - Partition #5, "Trouble Code".
Segment 6 - Partition #6, "Trouble Code".
Segment 7 - Partition #7, "Trouble Code".
Segment 8 - Partition #8, "Trouble Code".
LOCATION 60 - SENSOR LOW BATTERY COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
(8 segments, numerical data)
Location 60 contains the event code for a zone "Sensor Low Battery" for a 4+2 format. The digit programmed in this
location will be sent as the tens digit.. The zone ID will always be reported as the zone number (i.e. 9 for zone 29).
Any segment left as "0" will follow the Segment 1 selection.
Segment 1 - Partition #1, "Sensor Low Battery Code".
Segment 2 - Partition #2, "Sensor Low Battery Code".
Segment 3 - Partition #3, "Sensor Low Battery Code".
Segment 4 - Partition #4, "Sensor Low Battery Code".
Segment 5 - Partition #5, "Sensor Low Battery Code".
Segment 6 - Partition #6, "Sensor Low Battery Code".
Segment 7 - Partition #7, "Sensor Low Battery Code".
Segment 8 - Partition #8, "Sensor Low Battery Code".
LOCATION 61- SENSOR MISSING COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments,
numerical data)
Location 61 contains the event code for a zone "Sensor Missing" for a 4+2 format. The digit programmed in this
location will be sent as the tens digit.. The zone ID will always be reported as the zone number (i.e. 9 for zone 29).
Any segment left as "0" will follow the Segment 1 selection.
Segment 1 - Partition #1, "Sensor Missing Code".
Segment 2 - Partition #2, "Sensor Missing Code".
Segment 3 - Partition #3, "Sensor Missing Code".
Segment 4 - Partition #4, "Sensor Missing Code".
Segment 5 - Partition #5, "Sensor Missing Code".
Segment 6 - Partition #6, "Sensor Missing Code".
Segment 7 - Partition #7, "Sensor Missing Code".
Segment 8 - Partition #8, "Sensor Missing Code".
LOCATION 62 - DURESS COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments, numerical
data)
Location 62 contains the tens and ones digits that will be sent for a 4+2 format if the Duress code is enabled in
location 44. Segment 1 contains the tens digit, segment 2 contains the ones digit.
LOCATION 63 - KEYPAD AUXILIARY 1 COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments,
numerical data )
Location 63 contains the tens and ones digits that will be sent for a 4+2 format if the keypad "Auxiliary 1" (FIRE) is
enabled in the partition feature selection . Segment 1 contains the tens digit, segment 2 contains the ones digit.
LOCATION 64 - KEYPAD AUXILIARY 2 COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments,
numerical data)
Location 64 contains the tens and ones digits that will be sent for a 4+2 format if the keypad "Auxiliary 2" (MEDICAL)
is enabled in the partition feature selection. Segment 1 contains the tens digit, segment 2 contains the ones digit.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Interlogix NX-8 - Security NetworX System and is the answer not in the manual?

GE Interlogix NX-8 - Security NetworX System Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320 power supply12 VDC Regulated 2 AMPS + Control
Loop Specifications IconLoop Specifications
standard loop resistance300 Ohms Maximum
2-wire smokes resistance30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
built-in siren driver2-tone (Temporal and Yelp)
LED keypad current draw130 mA max.
Weight and Dimensions IconWeight and Dimensions
metal enclosure dimensions11.25" Wide x 11.25" High x 3.50" Deep
shipping weight9 lbs.
LED keypad dimensions6.4" Wide x 4.0" High x 1.1" Deep
NX-148 LCD keypad dimensions6.4" Wide x 5.3" High x 1.0" Deep