EasyManua.ls Logo

GE B30 UR Series

GE B30 UR Series
582 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GE Multilin B30 Bus Differential System 5-103
5 SETTINGS 5.5 FLEXLOGIC
5
ELEMENT:
Breaker control
BREAKER 1 OFF CMD
BREAKER 1 ON CMD
BREAKER 1 ΦA BAD ST
BREAKER 1 ΦA INTERM
BREAKER 1 ΦA CLSD
BREAKER 1 ΦA OPEN
BREAKER 1 ΦB BAD ST
BREAKER 1 ΦA INTERM
BREAKER 1 ΦB CLSD
BREAKER 1 ΦB OPEN
BREAKER 1 ΦC BAD ST
BREAKER 1 ΦA INTERM
BREAKER 1 ΦC CLSD
BREAKER 1 ΦC OPEN
BREAKER 1 BAD STATUS
BREAKER 1 CLOSED
BREAKER 1 OPEN
BREAKER 1 DISCREP
BREAKER 1 TROUBLE
BREAKER 1 MNL CLS
BREAKER 1 TRIP A
BREAKER 1 TRIP B
BREAKER 1 TRIP C
BREAKER 1 ANY P OPEN
BREAKER 1 ONE P OPEN
BREAKER 1 OOS
Breaker 1 open command initiated
Breaker 1 close command initiated
Breaker 1 phase A bad status is detected (discrepancy between the 52/a and
52/b contacts)
Breaker 1 phase A intermediate status is detected (transition from one
position to another)
Breaker 1 phase A is closed
Breaker 1 phase A is open
Breaker 1 phase B bad status is detected (discrepancy between the 52/a and
52/b contacts)
Breaker 1 phase A intermediate status is detected (transition from one
position to another)
Breaker 1 phase B is closed
Breaker 1 phase B is open
Breaker 1 phase C bad status is detected (discrepancy between the 52/a and
52/b contacts)
Breaker 1 phase A intermediate status is detected (transition from one
position to another)
Breaker 1 phase C is closed
Breaker 1 phase C is open
Breaker 1 bad status is detected on any pole
Breaker 1 is closed
Breaker 1 is open
Breaker 1 has discrepancy
Breaker 1 trouble alarm
Breaker 1 manual close
Breaker 1 trip phase A command
Breaker 1 trip phase B command
Breaker 1 trip phase C command
At least one pole of breaker 1 is open
Only one pole of breaker 1 is open
Breaker 1 is out of service
BREAKER 2 to 6 Same set of operands as shown for BREAKER 1
ELEMENT:
Bus differential
BUS 1 OP
BUS 1 DPO
BUS 1 BIASED OP A
BUS 1 BIASED OP B
BUS 1 BIASED OP C
BUS 1 BIASED PKP A
BUS 1 BIASED PKP B
BUS 1 BIASED PKP C
BUS 1 UNBIASED OP A
BUS 1 UNBIASED OP B
BUS 1 UNBIASED OP C
BUS 1 BIASED DPO A
BUS 1 BIASED DPO B
BUS 1 BIASED DPO C
BUS 1 UNBIASED DPO A
BUS 1 UNBIASED DPO B
BUS 1 UNBIASED DPO C
BUS 1 DIR A
BUS 1 DIR B
BUS 1 DIR C
BUS 1 SAT A
BUS 1 SAT B
BUS 1 SAT C
At least one phase of the bus differential characteristic has operated
At least one phase of the bus differential characteristic has dropped out
Phase A biased differential function has operated
Phase B biased differential function has operated
Phase C biased differential function has operated
Phase A biased differential function has picked up
Phase B biased differential function has picked up
Phase C biased differential function has picked up
Phase A unbiased differential function has operated
Phase B unbiased differential function has operated
Phase C unbiased differential function has operated
Phase A biased differential function has dropped out
Phase B biased differential function has dropped out
Phase C biased differential function has dropped out
Phase A unbiased differential function has dropped out
Phase B unbiased differential function has dropped out
Phase C unbiased differential function has dropped out
Phase A directional principle has picked up
Phase B directional principle has picked up
Phase C directional principle has picked up
CT saturation is detected in phase A
CT saturation is detected in phase B
CT saturation is detected in phase C
BUS 2 Same set of operands as shown for BUS 1
ELEMENT:
CT trouble
CT TROUBLE1 OP
CT TROUBLE1 OP A
CT TROUBLE1 OP B
CT TROUBLE1 OP C
At least one phase of CT Trouble Zone 1 is operated
Phase A of CT trouble zone 1 has operated
Phase B of CT trouble zone 1 has operated
Phase C of CT trouble zone 1 has operated
CT TROUBLE 2 Same set of operands as shown for CT TROUBLE 1
ELEMENT:
Digital counters
Counter 1 HI
Counter 1 EQL
Counter 1 LO
Digital counter 1 output is ‘more than’ comparison value
Digital counter 1 output is ‘equal to’ comparison value
Digital counter 1 output is ‘less than’ comparison value
Counter 2 to 8 Same set of operands as shown for Counter 1
Table 5–7: B30 FLEXLOGIC OPERANDS (Sheet 2 of 6)
OPERAND TYPE OPERAND SYNTAX OPERAND DESCRIPTION

Table of Contents

Related product manuals