EasyManua.ls Logo

GE B30 UR Series

GE B30 UR Series
582 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-22 B30 Bus Differential System GE Multilin
3.2 WIRING 3 HARDWARE
3.2.8 RS232 FACEPLATE PORT
A 9-pin RS232C serial port is located on the B30 faceplate for programming with a computer. All that is required to use this
interface is a computer running the EnerVista UR Setup software provided with the relay. Cabling for the RS232 port is
shown in the following figure for both 9-pin and 25-pin connectors.
The baud rate for this port is fixed at 19200 bps.
Figure 3–22: RS232 FACEPLATE PORT CONNECTION
3.2.9 CPU COMMUNICATION PORTS
a) OVERVIEW
In addition to the faceplate RS232 port, the B30 provides a rear RS485 communication port.
The CPU modules do not require a surge ground connection.

Table of Contents

Related product manuals