B-28 B30 Bus Differential System GE Multilin
B.4 MEMORY MAPPING APPENDIX B
B
3FA9 ...Repeated for Field Unit Transducer 8
Field Unit Identifiers (Read Only) (8 modules)
3FB8 Attached Field Unit 1 Serial Number --- --- 1 F205 (none)
3FBE Attached Filed Unit 1 Port Number --- --- 1 F001 0
3FBF Attached Field Unit 1 Type 0 to 3 --- 1 F243 0 (CC-05)
3FC0 Field Unit 1 Status 0 to 4 --- 1 F262 0 (Disabled)
3FC1 ...Repeated for Field Unit 2
3FCA ...Repeated for Field Unit 3
3FD3 ...Repeated for Field Unit 4
3FDC ...Repeated for Field Unit 5
3FE5 ...Repeated for Field Unit 6
3FEE ...Repeated for Field Unit 7
3FF7 ...Repeated for Field Unit 8
Passwords (Read/Write Command)
4000 Command Password Setting 0 to 4294967295 --- 1 F202 (none)
Passwords (Read/Write Setting)
400A Setting Password Setting 0 to 4294967295 --- 1 F202 (none)
Passwords (Read/Write)
4014 Command Password Entry 0 to 4294967295 --- 1 F202 (none)
401E Setting Password Entry 0 to 4294967295 --- 1 F202 (none)
Passwords (Read Only)
4028 Command Password Status 0 to 1 --- 1 F102 0 (Disabled)
4029 Setting Password Status 0 to 1 --- 1 F102 0 (Disabled)
Passwords (Read/Write Setting)
402A Command Password Access Timeout 5 to 480 min 1 F001 5
402B Setting Password Access Timeout 5 to 480 min 1 F001 30
402C Invalid Password Attempts (before lockout) 2 to 5 --- 1 F001 3
402D Password Lockout Duration 5 to 60 min 1 F001 5
Passwords (Read/Write)
402E Password Access Events 0 to 1 --- 1 F102 0 (Disabled)
Passwords (Read/Write Setting)
402F Local Setting Auth 1 to 4294967295 --- 1 F300 1
4031 Remote Setting Auth 0 to 4294967295 --- 1 F300 1
4033 Access Auth Timeout 5 to 480 min 1 F001 30
User Display Invoke (Read/Write Setting)
4040 Invoke and Scroll Through User Display Menu
Operand
0 to 4294967295 --- 1 F300 0
LED Test (Read/Write Setting)
4048 LED Test Function 0 to 1 --- 1 F102 0 (Disabled)
4049 LED Test Control 0 to 4294967295 --- 1 F300 0
Preferences (Read/Write Setting)
404F Language 0 to 5 --- 1 F531 0 (English)
4050 Flash Message Time 0.5 to 10 s 0.1 F001 10
4051 Default Message Timeout 10 to 900 s 1 F001 300
4052 Default Message Intensity 0 to 3 --- 1 F101 0 (25%)
4053 Screen Saver Feature 0 to 1 --- 1 F102 0 (Disabled)
4054 Screen Saver Wait Time 1 to 65535 min 1 F001 30
4055 Current Cutoff Level 0.002 to 0.02 pu 0.001 F001 20
4056 Voltage Cutoff Level 0.1 to 1 V 0.1 F001 10
Table B–10: MODBUS MEMORY MAP (Sheet 20 of 64)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT