GE Multilin C60 Breaker Protection System A-7
APPENDIX A A.1 PARAMETER LISTS
A
7284 SRC 4 Sb VA Source 4 phase B apparent power
7286 SRC 4 Sc VA Source 4 phase C apparent power
7288 SRC 4 PF --- Source 4 three-phase power factor
7289 SRC 4 Phase A PF --- Source 4 phase A power factor
7290 SRC 4 Phase B PF --- Source 4 phase B power factor
7291 SRC 4 Phase C PF --- Source 4 phase C power factor
7424 SRC 1 Pos Watthour kWh Source 1 positive Watthour
7426 SRC 1 Neg Watthour Wh Source 1 negative Watthour
7428 SRC 1 Pos varh varh Source 1 positive varhour
7430 SRC 1 Neg varh varh Source 1 negative varhour
7440 SRC 2 Pos Watthour kWh Source 2 positive Watthour
7442 SRC 2 Neg Watthour Wh Source 2 negative Watthour
7444 SRC 2 Pos varh varh Source 2 positive varhour
7446 SRC 2 Neg varh varh Source 2 negative varhour
7456 SRC 3 Pos Watthour kWh Source 3 positive Watthour
7458 SRC 3 Neg Watthour kWh Source 3 negative Watthour
7460 SRC 3 Pos varh varh Source 3 positive varhour
7462 SRC 3 Neg varh varh Source 3 negative varhour
7472 SRC 4 Pos Watthour Wh Source 4 positive Watthour
7474 SRC 4 Neg Watthour Wh Source 4 negative Watthour
7476 SRC 4 Pos varh varh Source 4 positive varhour
7478 SRC 4 Neg varh varh Source 4 negative varhour
7552 SRC 1 Frequency Hz Source 1 frequency
7554 SRC 2 Frequency Hz Source 2 frequency
7556 SRC 3 Frequency Hz Source 3 frequency
7558 SRC 4 Frequency Hz Source 4 frequency
7680 SRC 1 Demand Ia Amps Source 1 phase A current demand
7682 SRC 1 Demand Ib Amps Source 1 phase B current demand
7684 SRC 1 Demand Ic Amps Source 1 phase C current demand
7686 SRC 1 Demand Watt Watts Source 1 real power demand
7688 SRC 1 Demand var Vars Source 1 reactive power demand
7690 SRC 1 Demand Va VA Source 1 apparent power demand
7696 SRC 2 Demand Ia Amps Source 2 phase A current demand
7698 SRC 2 Demand Ib Amps Source 2 phase B current demand
7700 SRC 2 Demand Ic Amps Source 2 phase C current demand
7702 SRC 2 Demand Watt Watts Source 2 real power demand
7704 SRC 2 Demand var Vars Source 2 reactive power demand
7706 SRC 2 Demand Va VA Source 2 apparent power demand
7712 SRC 3 Demand Ia Amps Source 3 phase A current demand
7714 SRC 3 Demand Ib Amps Source 3 phase B current demand
7716 SRC 3 Demand Ic Amps Source 3 phase C current demand
7718 SRC 3 Demand Watt Watts Source 3 real power demand
7720 SRC 3 Demand var Vars Source 3 reactive power demand
7722 SRC 3 Demand Va VA Source 3 apparent power demand
7728 SRC 4 Demand Ia Amps Source 4 phase A current demand
7730 SRC 4 Demand Ib Amps Source 4 phase B current demand
7732 SRC 4 Demand Ic Amps Source 4 phase C current demand
Table A–1: FLEXANALOG DATA ITEMS (Sheet 7 of 13)