GE Druck DPI 620 User Manual

GE Druck DPI 620
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
GE
Sensing & Inspection Technologies
Druck DPI 620
advanced modular calibrator
user manual - K0449

Table of Contents

Other manuals for GE Druck DPI 620

Question and Answer IconNeed help?

Do you have a question about the GE Druck DPI 620 and is the answer not in the manual?

GE Druck DPI 620 Specifications

General IconGeneral
Measurement ParametersPressure, electrical, temperature
IP RatingIP54
HART CommunicationYes
Temperature MeasurementRTD, Thermocouple
DisplayColor
Communication InterfacesUSB
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Loop Power24 V

Summary

Chapter 2: Prepare the instrument

2.5 The battery

Information on the Li-Polymer battery, its condition, installation, charging, and operating time.

2.10 Menu sequence

Overview of the instrument's menu structure, including configuration, status, and task selection.

2.11 Measure and source operations

Procedures for setting up measure and source functions, including process and automation options.

2.12 The Advanced menu options

Access to advanced settings like HART resistor, standards, calibration, and setup files.

2.12.1 Advanced: Calibration options

Steps for calibrating the instrument and changing the calibration PIN.

Chapter 3: Electrical and IDOS operations

3.2 Measure and source operations

Procedures for measuring and sourcing electrical values, including current, voltage, and frequency.

3.3 Measure pressure: IDOS option

Instructions for assembling and using an IDOS module to measure pressure.

Chapter 4: Pressure indicator operation (MC 620)

4.3 Pressure connections

Procedures for making pressure connections using quick-fit adaptors and proper sealing.

4.4 Measure pressure

Steps to set up and perform pressure measurements, including leak tests and zeroing the module.

Chapter 5: Instrument communications

5.2 Connect to a computer (USB)

Step-by-step guide for connecting the DPI 620 to a computer using a USB mini Type B cable.

Chapter 6: Datalog operation

6.3 Data Logging

Steps to perform data logging, including task selection, filename, trigger, and start.

Chapter 7: Documenting functions

7.2 Analysis

How to compare data from two channels, calculate errors, and get pass/fail indications.

Chapter 8: HART® device operations

8.5 Start HART menu operations

Steps to start HART device search and initiate communications.

Chapter 9: Maintenance procedures