– 29 –
(Continued next page)
Fault 
Code 
Fault Name  Description Repair Action
10 Mode Shift Feedback 
Monitor
Signal feedback state from the mode shifter 
(agitate or spin) and the state requested by 
the control are not the same and the basket 
or agitator is rotating faster than 3 - 4 RPM. 
Agitate mode feedback signal is no voltage.
 Check mode shifter coupler for 
damage and the ability to slide 
in and out freely.
 Use ohm meter to ensure 
harness shows continuity to the 
mode shifter from the control.
 Check resistance of mode 
shifter motor (approximately 
5.7K ohms).
 Check for 120 VAC to the mode 
shifter motor at the control J512 
connector.
 If voltage is present and no 
operation, replace the mode 
shifter.
11 Clock Monitor 1.  AC power line frequency is not 60Hz.
2.  Software failure.
1.  Check the frequency of the AC 
power outlet. If it is more than a 
IHZ+]RႇRI+]QRWLI\XWLOLW\
company.
2.  If house frequency is good, 
update software.
12 Redundant Flood 
Condition
Backup Processor received an extended 
period of pressure readings that is nearing 
RYHUÀRZOHYHOV3UHVVXUH´
Voltage Output must be present. Could 
PHDQZDWHUGLGJHWWKDWKLJKGXHWREULHÀ\
stuck water valve. Voltage output of Sensor 
too high for actual water level because of 
Sensor or water in Pressure tube increasing 
pressure.
 Check pressure tube for 
trapped water. 
 Check Each Valves Operation; 
(Replace Water Valve and send 
back to GE).
 Check the output voltage from 
the pressure sensor to ensure 
it matches the water level in 
the basket according to the 
pressure sensor chart.
13 Redundant Lid 
Unlocked
In spin mode, the lid switch feedback 
has voltage (lid closed), for more than 
5 seconds the motor speed feedback 
assumes the basket is spinning > 4 - 5 RPM 
when the lid lock feedback has no voltage 
(Lid Unlocked).
Lid Switch Feedback has no Voltage 
when the BRPM is > 4 - 5 RPM.
 Check lid switch continuity at 
J513 on the control.
 Check continuity of lid lock 
position. Opened or Closed. 
 Check for proper operation 
of lid lock. 120 VAC while 
activating.
 Check lid lock wiring harness 
from the control to lock 
assembly.
14 Lid Lock Fault Signal received by control is indicating the 
lock will not lock or unlock when requested 
or the lid switch is indicating open when the 
signal received indicated locked.
 Verify that the lid lock is not 
blocked by any external debris.
 Check lid switch continuity at 
J513 on the control.
 Check continuity of lid lock 
position. Opened or Closed. 
 Check for proper operation 
of lid lock. 120 VAC while 
activating.
 Check lid lock wiring harness 
from the control to lock 
assembly.
 If lid lock assembly and 
harness are OK, update the 
software.
15 Water Temp Sensor 
Invalid
1. Thermistor disconnected/not present.
2. Failed thermistor
  
Check thermistor resistance 
from connector J701 on the 
control board. Validate the 
resistance matches the table in 
mini-manual.
 Check wiring harness and 
connections.
 Replace thermistor.